Option 2 (no CAN keypad connected to network):
1. Remove power from module.
2. Move DIP switches 4-6 to the “ON” position.
3. Connect module to CAN network.
4. Connect power and GND to module (J1 P4,16 and J1 P7,19).
5. Wait about 5 seconds. LED will flash continuously.
6. Press any transmitter button for about 5 seconds until LED
pattern changes, then release. This trains the first transmitter.
7. Press any button of 2nd transmitter, LED pattern changes
immediately. This synchs the 2nd transmitter.
8. Repeat step 7 until all transmitters are trained.
9. Remove power from module.
10. Move DIP switches 4-6 to normal position and verify DIP
switches 1-3 are in proper position.
11. Reconnect power to module.
12. Verify that FOBs are synched to the CAN module. CAN module
needs to be connected to a valid CAN network (2+ modules on
network) or CAN must be disabled to verify functionality.
Notes:
Up to 10 transmitters can be synched with a module. If a 11th
transmitter is added an earlier transmitter becomes invalid.
All transmitters must be trained together. Training at least one
key fob after putting the module into train mode erases all
previous FOBs.
If you place the system in learn mode and teach nothing, the
system will return to a normal mode in 60 seconds.
The memory for codes will not be erased if power is removed
10