EasyManua.ls Logo

Trisan S8 - Other Appliance Test Categories; Other Tests: Class I 250 V Insulation Resistance; Other Tests: Class II 250 V Insulation Resistance; Other Tests: Class I Run Test

Trisan S8
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
TRISAN S8 Appliance categories and test sequences
OTHER APPLIANCES TESTS
4 CLASS I 250V insulation resistance test
Suitable appliance category for testing any earthed equipment with protection devices installed that have failed the
standard earthed appliance insulation strength test at 500Vdc. There must be evidence that the appliance tested does
have a protection device installed.
Select CLASS I 250V from OTHER APPLIANCE
Press START
Measures: Electrical continuity (A –N) …………….. less than 100k ohm……………………………….. for PASS
Earth resistance (socket earth to chassis earth with earth probe connect)…….less than 1 ohm…….PASS
Insulation resistance (A -N short to EARTH)……….. greater than 1M ohm……………………PASS
5 CLASS II 250 V insulation resistance test
Suitable appliance category for testing any double insulated equipment with protection devices installed that have
failed the standard earthed appliance insulation strength test at 500Vdc. There must be evidence that the appliance
tested does have protection devices installed. A cloak or probe must be employed in contact with the insulation sur-
faces of the appliance during testing until complete.
Select CLASS II 250V from OTHER APPLIANCE
Press START
Measures: Electrical continuity (A –N) …………….. less than 100k ohm………………………………..for PASS
Insulation resistance (A - N to CLOAK/PROBE)………..greater than 1M ohm………………… PASS
6 CLASS I Run test
Suitable appliance category for testing any earthed equipment in which insulation testing has failed electrical continu-
ity test. The appliance has a soft switch (see definitions). Run tests can be dangerous to the operator. Ensure the
equipment is in-service and wear appropriate protective clothing before use.
Select CLASS I Run test from OTHER APPLIANCE
Press START
Use RUN TEST socket
Press START
WARNING! Appliance will operate…...Ensure moving parts are free to move
Press START
Testing in progress
Measures: Electrical continuity (A –N) …………….. less than 100k ohm………………………………..for PASS
Earth resistance (socket earth to chassis earth with earth probe connect)…….less than 1 ohm…….PASS
Leakage current (A and N to earth chassis and SE) …….. less than 5mA.………………… PASS