INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY
Fig.27
CLEANING THE INLET FILTER
It is recommended that the filter is periodically
cleaned in order to maintain the performance of
the shower. It is essential that this operation is
carried out by a competent person.
Switch off the electricity supply at the mains.
The inlet filter is situated in the inlet pipe which
is part of the solenoid valve (fig.27).
To gain access to the filter will require the
trimplate to be removed and disconnecting
and removal of the compression fitting.
Also, depending on the incoming pipework
arrangements, if there is not enough slack in the
pipework, it could mean the removal of the unit
from the wall.
When cleaning the wire mesh filter, do not use
a sharp object, as it will cause damage. It is
preferable to use an old toothbrush or similar.