Installation must comply with Water Regulations and Bylaws, covering pressure and site conditions.
Details running water pressure, static pressure, minimum flow rate, and temperature requirements.
Lists essential precautions to avoid freezing, improper connections, and unsafe operation.
Instructions on pipework layout, jointing, pipe entry, and isolating valves for safe installation.
Details suitable water systems, including gravity, combination boilers, and thermal storage.
Steps for fitting the mounting plate and connecting the mixer to the pipework.
Importance of regular testing to prevent scalding and ensure user safety.
Conforms to HTM 04-01 for healthcare; details temperature setting and thermal shut-off tests.
Guide on adjusting the maximum temperature stop and fitting the control lever.
Procedure for measuring and recording water temperatures and pressures for performance checks.
Identifies common issues like water temperature problems and flow rate issues with their causes and actions.
Installation must comply with Water Regulations and Bylaws, covering pressure and site conditions.
Details running water pressure, static pressure, minimum flow rate, and temperature requirements.
Lists essential precautions to avoid freezing, improper connections, and unsafe operation.
Instructions on pipework layout, jointing, pipe entry, and isolating valves for safe installation.
Details suitable water systems, including gravity, combination boilers, and thermal storage.
Steps for fitting the mounting plate and connecting the mixer to the pipework.
Importance of regular testing to prevent scalding and ensure user safety.
Conforms to HTM 04-01 for healthcare; details temperature setting and thermal shut-off tests.
Guide on adjusting the maximum temperature stop and fitting the control lever.
Procedure for measuring and recording water temperatures and pressures for performance checks.
Identifies common issues like water temperature problems and flow rate issues with their causes and actions.
The Triton Elina is a sequential built-in thermostatic mixer valve designed for showering applications. It is Kiwa certified (Type 3 TMV, 86002260), indicating compliance with specific performance standards, particularly for healthcare premises (D 08 specification).
The Triton Elina thermostatic mixer valve blends hot and cold water supplies to deliver a constant, safe showering temperature. It features anti-scald protection, which means that if there is a loss of flow to either incoming supply, the water from the shower will stop or be significantly reduced until both supplies are restored, preventing scalding. The mixed water temperature can be adjusted from cold to a pre-set top limit, with full anti-scald protection throughout the range. The valve is designed for built-in installation within a solid wall, stud partition wall, dry-lined wall, or fixed to a shower cubicle or panel.