2181355F - October 2018
Installation and
operating
instructions
Installers please note -
these InstructIons are to be left wIth the user
T90sr
electric shower
! IMPORTANT !
Under *NO circumstances should
this shower be connected directly
to a mains water supply.
It is designed for GRAVITY FED
COLD WATER systems ONLY !
*Failure to comply WILL invalidate product warranty
European Union Registered Design No. 003154467-0003/0004
The showerhead and hose supplied with this product are a safety
critical part of your shower. Failure to use genuine Triton parts
may cause injury and invalidate your guarantee.

Other manuals for Triton T90SR

Questions and Answers

  • V
    Victoria ButlerAug 18, 2025
    How to fix a Triton T90SR Bathroom Fixtures shower with no water flow?
    • H
      Heather PenaAug 18, 2025
      If your Triton Bathroom Fixture shower isn't working and no water is flowing, here's what to check: * **Power Supply:** Check the power supply by renewing or resetting the fuse or circuit breaker. If the issue persists, consult a qualified electrician. Also, check other appliances and contact your local Electricity Supply Company if necessary. * **Water Supply:** Ensure isolating valves are fully open and check for blockages in the inlet filter or pipework. * **Unit Malfunction:** If the above steps don't resolve the issue, have the unit checked by a professional. Contact Customer Service.
  • A
    Amber MendozaAug 20, 2025
    Why is my Triton T90SR shower water too hot?
    • M
      Matthew WalkerAug 20, 2025
      If the water from your Triton Bathroom Fixture is too hot, try these solutions: * **Increase Flow Rate:** Adjust the temperature control to increase the water flow. * **Clean Showerhead:** Remove and clean or replace any blocked sprayplate in the showerhead. * **Check for Blockages:** Make sure stop valves are fully open and inspect the inlet filter for any blockages. * **Adjust for Ambient Temperature:** Readjust the flow rate to increase the flow, or select ‘economy’ power.
  • C
    Chad WelchAug 23, 2025
    What to do if Triton T90SR shower water is too cold?
    • B
      brownheatherAug 23, 2025
      If the water from your Triton Bathroom Fixture is too cool or cold, consider the following: * **Reduce Flow Rate:** Adjust the temperature control to reduce the water flow. * **Adjust for Ambient Temperature:** Switch to the full power setting and readjust the flow rate using the temperature control until you reach the required temperature. * **Electrical Issues:** Have the shower unit checked by a competent electrician or contact Customer Service to investigate potential electrical malfunctions or safety cut-out operation.
  • J
    John ButlerAug 26, 2025
    Why is the water too hot in my Triton Bathroom Fixture shower?
    • A
      Annette TaylorAug 26, 2025
      If your Triton Bathroom Fixture shower's water is too hot, try increasing the flow rate via the temperature control. Also, check the shower head for blockages and clean or replace the sprayplate if needed. Ensure stop valves are fully open and the inlet filter isn't blocked. If the ambient water temperature has increased, readjust the flow rate to increase flow or select economy power.
  • C
    Cathy JuarezAug 28, 2025
    How to fix a Triton Bathroom Fixture shower with no water flow?
    • T
      Theodore SullivanAug 28, 2025
      If your Triton Bathroom Fixture shower is inoperable with no water flow, first check for an interrupted power supply by looking for a blown fuse or tripped circuit breaker; renew or reset it. If it fails again, consult a qualified electrician. Also, check other appliances to see if there's a power cut, and contact your local Electricity Supply Company if necessary. Ensure the shower has a water supply by checking if isolating valves are fully open and inspecting for blockages in the inlet filter or pipework. If these steps don't resolve the issue, have the unit checked by contacting Customer Experience.
  • J
    Judith PowellAug 30, 2025
    What to do if Triton Bathroom Fixture shower performance drops?
    • S
      Sarah RoachAug 30, 2025
      If you experience a gradual reduction in water flow from your Triton Bathroom Fixture shower, check for water starvation to the unit. Ensure the filter isn't blocked by isolating the electricity supply and removing the cover. Verify the cold water cistern is full, the water supply pipe isn't blocked or airlocked, and there's no simultaneous demand from the cistern during showering. You can also try repriming the unit without electricity. Refer to the Commissioning section for instructions on repriming.
  • E
    Evan JeffersonSep 2, 2025
    Why is my Triton Bathroom Fixture shower water too cold?
    • V
      Victoria BauerSep 2, 2025
      If the water from your Triton Bathroom Fixture shower is too cool or cold, try reducing the flow rate via the temperature control. If that doesn't work, switch to the full power setting and readjust the flow rate using the temperature control until you reach the required temperature. If these steps don't help, there may be an electrical malfunction or the safety cut-out has operated; have the shower unit checked by a competent electrician or contact Customer Experience.
  • S
    Savannah KennedySep 4, 2025
    Why does my Triton T90SR Bathroom Fixtures shower cycle between hot and cold?
    • T
      Timothy Goodman MDSep 5, 2025
      If the water temperature in your Triton Bathroom Fixture shower is cycling between hot and cool, the heater might be cycling on a thermal cut-out. Refer to the solutions for ‘Water too hot’ related to flow rate, showerhead blockage, and supply blockages. If the problem persists, contact Customer Service.
  • Q
    qcoffeySep 7, 2025
    Why does the water flow cease abruptly during use of my Triton Bathroom Fixture shower?
    • R
      Richard HardySep 7, 2025
      If the water flow from your Triton Bathroom Fixture shower ceases abruptly, the issue might be an interrupted power supply. Check for blown fuses or power cuts. If the pump is still operating, a solenoid valve malfunction could be the cause; switch off the shower immediately and have the solenoid checked by a competent electrician or contact Customer Experience. A faulty pump motor could also be the reason, in which case you should contact Customer Experience to have the unit checked.
  • K
    Kimberly JohnsonSep 9, 2025
    What to do if the pressure relief device has operated on my Triton Bathroom Fixture shower?
    • A
      angela78Sep 9, 2025
      If the pressure relief device on your Triton Bathroom Fixture has operated, causing water to be ejected, first check for a blocked shower head and clean or replace it. Also, inspect the flexible shower hose for twists or blockages, ensuring free passage through it; replace the hose if necessary. After addressing these issues, fit a new PRD. If the shower head wasn't removed during commissioning, fit a new PRD and recommission the unit with the shower head removed.

Summary

IMPORTANT SAFETY INFORMATION

GENERAL GUIDANCE NOTES

GENERAL INSTALLATION GUIDELINES

General installation guidelines and important notes.

PLUMBING INSTALLATION GUIDELINES

Guidelines for plumbing connections and requirements.

ELECTRICAL INSTALLATION GUIDELINES

Guidelines for electrical connections and safety.

GENERAL ADVICE TO USERS

COMMISSIONING ADVICE

Essential steps before initial operation to prevent damage.

ADVISORY - CLEANING

Recommended cleaning methods and warnings.

INSTALLATION CHECK LIST

SPECIFICATIONS

ELECTRICAL SPECIFICATIONS

Electrical power rating and MCB rating.

PLUMBING SPECIFICATIONS

Supply source, capacity, and connection details.

MATERIALS SPECIFICATIONS

Materials used for shower components.

STANDARDS AND APPROVALS

Compliance with safety and regulatory standards.

DIMENSIONS & ENTRY POINTS

DIMENSIONS

Physical measurements of the shower unit.

ENTRY POINTS

Locations for water and cable entry.

ELECTRICAL REQUIREMENTS

EARTHING REQUIREMENT

Critical warning about earthing the appliance.

CIRCUIT PROTECTION GUIDELINES

Guidance on MCB and fuse ratings for protection.

CABLE CURRENT CAPACITY

Cable current capacities based on installation type.

CABLE SELECTION FACTORS

Notes on selecting appropriate cable size.

SITING OF THE SHOWER

MAINS WATER SUPPLY WARNING

Warning against connecting directly to mains water.

ADVISORY NOTES ON PIPING

Advice on pipe placement and hard water areas.

WATER REGULATIONS AND PLACEMENT

Requirements for showerhead placement and spill-over levels.

FLAT SURFACE MOUNTING REQUIREMENT

Importance of mounting on a flat surface for proper function.

PLUMBING INSTALLATION

OUTLET AS VENT INFORMATION

Outlet function as a vent, not to be connected to other devices.

PIPEWORK FLUSHING PROCEDURE

Flushing pipework to remove debris before connecting.

PIPEWORK SEALING ADVICE

Sealing around pipework to prevent water ingress.

ELECTRICAL INSTALLATION

POWER SWITCH-OFF SAFETY

Safety instruction to switch off power before proceeding.

ENTRY POINT DEVIATION WARNING

Consequence of deviating from approved cable entry points.

FIT TO THE WALL & CONNECT SUPPLIES

TRIMPLATE CUT-OUT CAUTION

Caution on cutting the trimplate for entry points.

HIDDEN CABLES;PIPES WARNING

Warning about hidden cables/pipes and using power tools.

FITTING AND WATER CONNECTION PROCEDURE

Step-by-step guide for fitting the unit and connecting water.

TEMPORARY SPINDLE LOCKING SCREW

Information about the temporary locking screw on the spindle.

TIGHT TERMINAL CONNECTIONS IMPORTANCE

Importance of tight terminal block screws to prevent overheating.

EARTH CONDUCTOR SLEEVING REQUIREMENT

Requirement for sleeving the earth conductor.

INSTALLATION

PRE-COVER FITTING CHECKS

Checks to perform before replacing the shower unit cover.

COVER FITTING PROCEDURE

Steps for fitting the shower unit cover correctly.

COVER RETAINING SCREWS WARNING

Warning about using only supplied screws for the cover.

COMMISSIONING

COMMISSIONING IMPORTANCE WARNING

Warning about the importance of correct commissioning.

COMMISSIONING PROCEDURE STEPS

Step-by-step guide for the initial flushing and priming process.

ELECTRICITY SUPPLY SWITCH-OFF

Instruction to switch off electricity before proceeding.

USER OPERATING INSTRUCTIONS

OPERATING THE SHOWER STEPS

Steps to start, stop, and isolate the shower.

HOT WATER RESTART WARNING

Warning about hot water expulsion on restart.

POWER SELECTOR EXPLANATION

Explanation of power settings (COLD, ECONOMY, HIGH).

ADJUSTING TEMPERATURE (ECONOMY;HIGH)

How to adjust temperature using the flow rate control.

DECREASING SHOWER TEMPERATURE

Turning control anti-clockwise makes water cooler.

INCREASING SHOWER TEMPERATURE

Turning control clockwise makes water warmer.

OPERATING FUNCTIONS EXPLAINED

Explains power indicator, low pressure cut-out, and safety features.

UNIT SHUT-OFF ADVICE

Advice on switching off the unit when not in use.

CLEANING THE FILTER

FILTER CLEANING PROCEDURE

Guidance for cleaning the inlet filter.

PRE-CLEANING POWER SHUT-OFF

Safety instruction to switch off power before cleaning.

POST-CLEANING UNIT PRIMING

Advice on priming the unit after filter replacement.

FAULT FINDING;TROUBLESHOOTING

NO WATER FLOW TROUBLESHOOTING

Troubleshooting steps for no water flow.

WATER TOO HOT TROUBLESHOOTING

Troubleshooting steps for water being too hot.

TEMPERATURE FLUCTUATION TROUBLESHOOTING

Troubleshooting for temperature fluctuations.

WATER TOO COOL;COLD TROUBLESHOOTING

Troubleshooting steps for water being too cool.

ABRUPT WATER FLOW CESSATION

Troubleshooting for abrupt cessation of water flow.

GRADUAL WATER FLOW REDUCTION

Troubleshooting for gradual reduction in water flow.

PRESSURE RELIEF DEVICE OPERATION

Troubleshooting when PRD has operated.

STOP BUTTON FAILURE TROUBLESHOOTING

Troubleshooting for failure to shut off.

PRD REPLACEMENT NOTE

Note on PRD replacement procedure.

SPARE PARTS LIST

SPARE PARTS DESCRIPTION AND NUMBERS

List of spare parts with descriptions and part numbers.

SHOWER CONTROLS QUICK GUIDE

STARTING AND STOPPING THE SHOWER

Simple steps to start and stop the shower.

ADJUSTING FLOW AND TEMPERATURE

How to adjust flow and temperature using controls.

SERVICE POLICY AND PROCEDURES

FAULT REPORTING PROCEDURE

Procedure to follow in case of a fault or complaint.

SPARE PARTS ORDERING POLICY

Information on ordering and supplying spare parts.

TRITON STANDARD GUARANTEE

GUARANTEE EXCLUSIONS

List of exclusions from the standard guarantee.

Triton T90SR Specifications

General IconGeneral
TypeElectric Shower
Temperature ControlStabilised
Shower Head Spray Patterns5
Start/Stop ButtonYes
MaterialPlastic
ADA CompliantNo
Warranty2 Years
FinishChrome
InstallationWall-mounted
Water Entry PointsRight Hand Side - Top, Bottom, Back