Patents: GB 2489547
GB 2495343
GB 2481878
2180834T - April 2021
T80Z FAST-FIT
electric shower
FOR YOUR SERVICE REFERENCE
NOTE DOWN THE PRODUCT CODE BELOW
(FROM THE FRONT OR TOP OF THE BOX)
ALTERNATIVELY REGISTER BY TEL: 024 7637 8321
INSTALLATION AND OPERATING INSTRUCTIONS
Please read this book thoroughly and familiarise yourself with all instructions before commencing
installation and keep it for future reference.
The shower installation MUST be carried out by a suitably qualified person, in the sequence of
this instruction book.
IMPORTANT SAFETY ADVICE
The shower unit MUST BE switched off at the
isolating switch when not in use. This is a
safety procedure recommended for all
electrical appliances.
The shower head and hose supplied with this
product are a safety critical part of your shower.
Failure to use genuine Triton parts may cause
injury and invalidate your guarantee.
THIS OFFER IS NOT VALID OUTSIDE THE UK
REGISTER ONLINE
ENTER A PRIZE DRAW
WIN
£100
LOVE2SHOP VOUCHERS
VISIT OUR WEBSITE TODAY
TRITONSHOWERS.CO.UK/REGISTER
PRODUCT REGISTRATION IS ONLY AVAILABLE
TO UNITS PURCHASED & INSTALLED IN THE UK

Questions and Answers

  • J
    Jon MilesAug 12, 2025
    How to fix a Triton Bathroom Fixture shower with no water flow?
    • J
      janet43Aug 12, 2025
      If your Triton Bathroom Fixture shower is inoperable with no water flow, first check the power supply by renewing or resetting the fuse or circuit breaker. If the issue persists, consult a qualified electrician. Additionally, a unit malfunction could be the cause. Check other appliances and, if necessary, contact your local Electricity Supply Co. to have the unit checked, or contact Customer Experience.
  • C
    Cynthia HernandezAug 16, 2025
    Why is the water too hot in my Triton Bathroom Fixture shower?
    • B
      Brenda PhillipsAug 16, 2025
      If the water from your Triton Bathroom Fixture shower is too hot, try the following: * Increase the flow rate via the temperature control. * Clean or replace the blocked sprayplate in the shower head. * Check if the stop valves are fully open and inspect the inlet filter for blockages. Also, readjust the flow rate to increase flow, or select ‘ECONOMY’ power.
  • M
    Michelle MccoyAug 19, 2025
    What to do if the pressure relief device on my Triton Bathroom Fixture shower is ejecting water?
    • B
      Bryan JacksonAug 20, 2025
      If the pressure relief device on your Triton Bathroom Fixture has operated, resulting in water being ejected from the PRD tube, it could be due to a blocked shower head. Clean or replace the blocked sprayplate and then fit a new PRD. It could also be due to a twisted or blocked flexible shower hose, so check for free passage through the hose and replace it if necessary, then fit a new PRD. Finally, ensure the shower head was removed during commissioning and fit a new PRD, commissioning the unit with the shower head removed.
  • W
    wangcameronAug 25, 2025
    Why does my Triton Bathroom Fixture shower go from hot to cold?
    • M
      Mrs. Diamond LloydAug 25, 2025
      If your Triton Bathroom Fixture shower varies from normal temperature to cold during use, it is likely that the water pressure has dropped below the minimum required. Wait until the water pressure returns to normal.
  • R
    Randy PorterAug 27, 2025
    Why is the water too cold in my Triton Bathroom Fixture shower?
    • S
      Savannah GonzalezAug 27, 2025
      If the water from your Triton Bathroom Fixture shower is too cool or cold, try the following: * Reduce the flow rate via the temperature control. * If tank fed, replumb to mains water supply. * If mains fed, make sure that mains stopvalve is fully open and that there are no other restrictions in the supply while shower is in use. Additionally, you can fit a pump to give minimum pressure or readjust the flow rate to reduce flow. You might also select ‘HIGH’ power.
  • M
    mary83Aug 31, 2025
    Why does my Triton Bathroom Fixture shower alternate between hot and cold water?
    • J
      Jesse MooreAug 31, 2025
      If the water temperature in your Triton Bathroom Fixture shower cycles between hot and cool at intervals, it may be due to the heater cycling on the temperature limiter. Refer to the causes for 'Water too hot' (blocked shower head, blockage in supply, not enough water flowing through the shower) and take the appropriate actions. If the issue continues, contact Customer Experience.
  • S
    Sharon OliverSep 3, 2025
    What causes a Triton Bathroom Fixture shower to not shut off?
    • H
      Haley PayneSep 4, 2025
      If your Triton Bathroom Fixture shower fails to shut off, it could be due to a faulty start/stop switch, which would need replacing. Another cause could be debris in the solenoid, in which case the solenoid valve should be replaced.
  • D
    Derek SolomonSep 7, 2025
    What to do if my Triton Bathroom Fixture shower continues to run cold?
    • S
      Sydney LaneSep 7, 2025
      If your Triton Bathroom Fixture shower is producing water that is too cool or cold and this is a continued issue, it may be due to an electrical malfunction. Have the unit checked by a suitably qualified electrician or contact Customer Experience. Alternatively, the thermal safety cut-out device may have operated. In this case, have the unit checked by a suitably qualified engineer or contact Customer Experience.

Summary

Important Safety Advice

General Guidance Notes

General

General installation and usage guidelines.

Plumbing

Guidelines for water supply and pipe connections.

Electrical

Guidelines for electrical connections and safety.

General Advice to Users

Important Advice to Users

Key advice and warnings for users regarding operation and maintenance.

Specifications

Electrical Requirements

Siting of the Shower

Plumbing Installation

Electrical Installation

Fit to the Wall & Connect the Shower Supplies

Fitting Procedure

Step-by-step instructions for mounting the unit and making connections.

Commissioning Procedure

User Operating Instructions

Fault Finding and Troubleshooting

Triton T80ZFF FAST-FIT Specifications

General IconGeneral
TypeElectric Shower
Voltage230-240V
Temperature ControlStabilised
FinishWhite
InstallationWall Mounted
IP RatingIPX4
Thermal Cut-outYes
Cable Entry PointsTop, bottom, back
Heating ElementCopper
Power Rating8.5kW
Water PressureMinimum 1 Bar