EasyManua.ls Logo

Trojan TrojanUVMax Pro10 - SLEEVE CLEANING AND LAMP REPLACEMENT; Quartz Sleeve Cleaning Process; UV Lamp Replacement Procedure

Trojan TrojanUVMax Pro10
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION
OVERVIEW
WARRANTY
MAINTENANCE
OPERATION
Sleeve cleaning
Mineralsinthewaterslowlyformacoatingonthesleeve.Thiscoatingmustberemovedbecauseitreducesthe
amountofUVlightreachingthewater,therebyreducingdisinfectionperformance.Theneedtocleanthesleeve
willbeindicatedbyalowUValarm(flashingredindicatorlightbesidethesensoroncontrolpanel-seeControl
Panelsectionfordetails).
Note:LowUValarmsareforPro&PlusSeriesonly.IfyouownaBasicmodel,pleasecleanthesleeveregulary
(agoodruleofthumbis3-4timesperyear).
Whencleaningisrequired,followtheinstructionsbelowandre-installthecurrentlamp.
Lamp replacement
TheamountofUVlightcreatedbythelampdecreasesovertime,requiringthatthelampbereplaced.The
systemwillautomaticallynotifyyouwhenitistimetoreplacethelamp(thelampshouldlastapproximately24
months).Ifthelamprequiresreplacement,followtheinstructionsbelowandinstallanewlamp.NOTE:TheUV
systemisdesignedtooperatecontinuouslyandshouldnotbeshutoffforshortperiodsoftime,suchasovera
periodoflessthanthreeweeks.
Equipment required:
SLEEVE CLEANING & LAMP REPLACEMENT
Cloth must be
soft, lint-free, and
chemical-free. No
clean-wipes.
Scale remover
such as CLR
TM
or
Lime-Away
TM
.
Screwdirver of any
kind.
Cottom swab. Clean cotton, latex
or plastic gloves
are prefered.
17