Operating manual – air cleaner AirgoClean 10 E
1. Open the device cover(2) by rotating it counter-clockwise.
Note the mark(6) on the right-hand side of the device
cover. You have to rotate the device cover(2) from the
closed(7) to the open position(8).
2
6
8
7
2. Remove the device cover(2) from the device.
2
3. Pull the strip(9) to take the used HEPA filter(10) out of the
device.
10
9
4. Dispose of the used HEPA filter according to the national
regulations.
5. Take the new HEPA filter out of the plastic cover. The front
of the HEPA filter is fitted with a pre-filter made of synthetic
fibre and with the strip(9).