EN 6
Operating manual – air cleaner AirgoClean 10 E
Notice
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Visual inspection of the inside of the device for dirt
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, clean the inside of the
device with a vacuum cleaner.
5. Put the air filter back in.
Changing the HEPA filter
Notice
Do not operate the device without a HEPA filter
inserted!
Notice
The HEPA filter is not washable. Do not use water or
liquid cleaning agents to clean the HEPA filter.
• The HEPA filter has to be replaced as soon as it is dirty.
This is brought to light e.g. by a reduced capacity (see
chapter Errors and faults).
• Make sure that the HEPA filter is installed before switching
the device on.
• Without the HEPA filter, the device cannot fulfil its air
cleaner function, and the inside of the device will be soiled.
The HEPA filter should be replaced in case of heavy soiling.
The operating life is approx.6months, depending on the degree
of air pollution.
If required, visually inspect the HEPA filter for dirt.