6 EN
clamp meter BE44
Measuring ranges
Measuring
range
Resolution Accuracy Measuring range
exceeded
ACvoltage (V/AC)(**)
6V
60V
600V
750V
1mV
10mV
0.1V
1V
±(0.8%
+ 5digits)
OL will be indicated
on the display.
±(1.2 %
+ 5digits)
-
(*)
DCvoltage (V/DC)(**)
6V
60V
600V
1000V
1mV
10mV
0.1V
1V
±(0.8%
+ 5digits)
OL will be indicated
on the display.
±(1.0 %
+ 5digits)
Alternating current (A/AC)
60 A 0.01 A ±(2.5 %
+ 6digits)
OL will be indicated
on the display.
600 A 0.1 A OL will be indicated
on the display.
1000 A 1 A -
(*)
Direct current (A/DC)
60 A 0.01 A ±(3.0 %
+ 10digits)
OL will be indicated
on the display.
600 A 0.1 A ±(3.0 %
+ 6digits)
1000 A 1 A
Resistance (Ω)(***)
600 Ω 0.1 Ω ±(1.0 %
+ 5digits)
OL will be indicated
on the display.
6 kΩ 1 Ω
60 kΩ 10 Ω
600 kΩ 100 Ω
6MΩ 1 kΩ ±(1.5 %
+ 5digits)
60MΩ 10 kΩ ±(3.0 %
+ 10digits)
Frequency using measuring cables(Hz)(****)
9.999 Hz 0.001 Hz ±(1.0 %
+ 5digits)
The measuring
range is set
automatically.
99.99 Hz 0.01 Hz
999.9 Hz 0.1 Hz
9.999 kHz 1 Hz
99.99 kHz 10 Hz
999.9 kHz 100 Hz
9.999 MHz 1 kHz Not specified
Measuring
range
Resolution Accuracy Measuring range
exceeded
Frequency using clamp(Hz)(****)
40 Hz -
99.99 Hz
0.01 Hz ±(1.0 %
+ 5digits)
Not specified
100 Hz -
999.9 Hz
0.1 Hz
Duty cycle(******)
5%~
95%
0.1% ±(2.0 %
+ 7digits)
The measuring
range is set
automatically.
Capacitance (C)
40nF 10pF ±(5.0 %
+ 5digits)
The measuring
range is set
automatically. If a
capacitance of
more than 4000µF
is measured,
OLwill be indicated
on the display.
400nF 100pF
4µF 1nF
40µF 10nF
400µF 100nF
4000µF 1µF Not specified
Function Range
Diode measurement Test voltage: approx. 2.5V
Test current: approx. 0.6mA
Continuity check Acoustic signal at ≤20Ω
Acoustic signal possible at 20Ω–
150Ω
No acoustic signal at >150Ω
(*)
: When exceeding the measuring range, the measured
value might be displayed nonetheless.
Please observe the measuring range and the overvoltage
protection! Measurements above the given measuring
range are not permitted!
OL= outside limits
(**)
: internal resistance: 10MΩ
(***)
: open-circuit voltage <0.7V
(****)
: input sensitivity 1Vrms to 20Vrms
(*****)
: input current ≥8A
(******)
: input voltage: 4~ 10Vp-p,
frequency range: 4Hz~ 1kHz
Scope of delivery
1x Device
1x Red measuring cable
1x Black measuring cable
1x Label with safety information