6 EN
clamp meter BE44
Measuring ranges
Measuring
range
Resolution Accuracy Measuring range
exceeded
ACvoltage (V/AC)(**)
6V
60V
600V
750V
1mV
10mV
0.1V
1V
±(0.8%
+ 5digits)
OL will be indicated
on the display.
±(1.2 %
+ 5digits)
-
(*)
DCvoltage (V/DC)(**)
6V
60V
600V
1000V
1mV
10mV
0.1V
1V
±(0.8%
+ 5digits)
OL will be indicated
on the display.
±(1.0 %
+ 5digits)
Alternating current (A/AC)
60 A 0.01 A ±(2.5 %
+ 6digits)
OL will be indicated
on the display.
600 A 0.1 A OL will be indicated
on the display.
1000 A 1 A -
(*)
Direct current (A/DC)
60 A 0.01 A ±(3.0 %
+ 10digits)
OL will be indicated
on the display.
600 A 0.1 A ±(3.0 %
+ 6digits)
1000 A 1 A
Resistance (Ω)(***)
600 Ω 0.1 Ω ±(1.0 %
+ 5digits)
OL will be indicated
on the display.
6 kΩ 1 Ω
60 kΩ 10 Ω
600 kΩ 100 Ω
6MΩ 1 kΩ ±(1.5 %
+ 5digits)
60MΩ 10 kΩ ±(3.0 %
+ 10digits)
Frequency using measuring cables(Hz)(****)
9.999 Hz 0.001 Hz ±(1.0 %
+ 5digits)
The measuring
range is set
automatically.
99.99 Hz 0.01 Hz
999.9 Hz 0.1 Hz
9.999 kHz 1 Hz
99.99 kHz 10 Hz
999.9 kHz 100 Hz
9.999 MHz 1 kHz Not specified
Measuring
range
Resolution Accuracy Measuring range
exceeded
Frequency using clamp(Hz)(****)
40 Hz -
99.99 Hz
0.01 Hz ±(1.0 %
+ 5digits)
Not specified
100 Hz -
999.9 Hz
0.1 Hz
Duty cycle(******)
5%~
95%
0.1% ±(2.0 %
+ 7digits)
The measuring
range is set
automatically.
Capacitance (C)
40nF 10pF ±(5.0 %
+ 5digits)
The measuring
range is set
automatically. If a
capacitance of
more than 4000µF
is measured,
OLwill be indicated
on the display.
400nF 100pF
4µF 1nF
40µF 10nF
400µF 100nF
4000µF 1µF Not specified
Function Range
Diode measurement Test voltage: approx. 2.5V
Test current: approx. 0.6mA
Continuity check Acoustic signal at ≤20Ω
Acoustic signal possible at 20Ω–
150Ω
No acoustic signal at >150Ω
•
(*)
: When exceeding the measuring range, the measured
value might be displayed nonetheless.
Please observe the measuring range and the overvoltage
protection! Measurements above the given measuring
range are not permitted!
• OL= outside limits
•
(**)
: internal resistance: 10MΩ
•
(***)
: open-circuit voltage <0.7V
•
(****)
: input sensitivity 1Vrms to 20Vrms
•
(*****)
: input current ≥8A
•
(******)
: input voltage: 4~ 10Vp-p,
frequency range: 4Hz~ 1kHz
Scope of delivery
• 1x Device
• 1x Red measuring cable
• 1x Black measuring cable
• 1x Label with safety information
• 3x 1.5V battery AAA
• 1x Manual