clamp meter BE44
Intended use
This device is intended for measurements in the measuring
range specified in the technical data.
To use the device for its intended use, only use accessories and
spare parts which have been approved by Trotec.
Improper use
Do not use the device in potentially explosive atmospheres,
when wet or very humid.
Unauthorized modifications of the device are forbidden.
Personnel qualifications
People who use this device must:
be aware of the dangers that occur when working with
electric devices in damp areas.
take measures to protect themselves from direct contact
with live parts.
have read and understood the operating manual, especially
the Safety chapter.
Residual risks
Danger
Electric shock from insufficient insulation. Check the
device for damages and proper functioning before each
use.
If you notice damages, no longer use the device.
Do not use the device when the device or your hands
are damp or wet!
Do not use the device when the battery compartment
or the housing are open.
Danger
Electric shock from contact with live parts. Do not
touch any live parts. Secure neighbouring live parts by
insulating them or switching them off.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Caution
Keep a sufficient distance from heat sources.
Note
To avoid damages to the device, make sure that the
correct measuring range is selected before carrying out
a measurement.
If you are unsure, select the largest measuring range.
Unplug the cable before changing the measuring
range.
Note
To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.
Note
Do not use abrasive cleaners or solvents to clean the
device.
Information about the device
Device description
Using the clamp meter BE44 you can easily check the amperage
of alternating an direct currents, AC and DC voltages,
resistances, the power frequency or the continuity of circuits,
fuses and contacts.
Moreover, it can be used for the non-contact detection of
AC voltages in electrical fields, for testing the forward voltage of
diodes and to determine the duty cycle for frequency
measurements.
The current measurement is effected without contact via the
electromagnetic field, which is why the electric circuit doesn't
have to be interrupted for this method. Therefore, running
systems, which cannot be switched off separately, can also be
checked.
Owing to the galvanic isolation, the measuring signal is also
potential-free towards the variable to be measured.