EN 7
moisture measuring device BM12
Maintenance and repair
Battery change
A battery change is required, when the Battery indication(8)
lights up or the device can no longer be switched on.
Note
Make sure that the surface of the device is dry and the
device is switched off.
To change the batteries, please proceed as follows:
1. Remove the cover(6) from the device by sliding it in the
direction of the arrow.
2. Remove the old batteries from the device.
3. Insert the new batteries in the battery compartment with
correct polarity.
4. Slide the cover(6) back on the device.
Exchanging measuring tips
Exchange the measuring tips when they exhibit signs of wear
(e.g. oxidation, deformation, heavy, irremovable
contaminations).
ü Make sure that the device is switched off.
1. Remove the protective cap(1) from the device.
2. Detach the screwed-on measuring tips from the device.
3. Screw the new measuring tips into the device.
Cleaning
Clean the device with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Do not use any
sprays, solvents, alcohol-based cleaning agents or abrasive
cleaners, but only clean water to moisten the cloth.
Repair
Do not modify the device or install any spare parts. For repairs
or device testing, contact the manufacturer.