EasyManua.ls Logo

Trotec pac 2000 e - Page 11

Trotec pac 2000 e
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN 11
local air conditioner PAC 2000 E
Automatic switch-on
ü The device is switched off.
1. Press the TIMER button(23) until the arrow of the T-ON
indication(33) flashes on the remote control.
2. Select the desired number of hours by use of the Plus(18)
or Minus(19) buttons.
3. Press the TIMER button(23) again to save the setting.
ð The number of hours will be indicated on the segment
display(31) for approx. 5s.
ð The arrow of the T-ON indication(33) appears on the
remote control.
ð The timer setting equals the desired number of hours.
ð After the predefined time, the device switches itself on.
Notes regarding automatic switch-on:
If the device is disconnected from the power supply, all
settings for automatic switch-on are deleted.
Manually switching the device on disables the automatic
switch-on function.
If you select 0hours, the timer will be off.
Automatic switch-off
ü The device is switched on.
1. Press the TIMER button(23) until the arrow of the T-OFF
indication(33) flashes on the remote control.
2. Select the desired number of hours by use of the Plus(18)
or Minus(19) buttons.
ð The number of hours will be indicated on the segment
display(31) for approx. 5s.
ð The arrow of the T-OFF indication(33) appears on the
remote control.
ð The timer setting equals the desired number of hours.
ð After the predefined time, the device switches itself off.
Notes regarding automatic switch-off:
Pressing the ON/OFF button(17) deactivates the automatic
switch-off function.
Deleting the timer
1. Press the TIMER button(23).
ð The remaining time is indicated on the display.
2. Press the TIMER button(23) again within 5s to delete the
timer setting.
Night mode
Night mode can be activated when in cooling mode.
Night mode comes with the following settings:
After 1 hour the preset temperature is increased by 1°C.
After another 2hours the preset temperature will be
increased by 2°C. Then the temperature is kept constant.
The fan speed is preset to the lowest stage and cannot be
adjusted.
To activate night mode, please proceed as follows:
1. Select cooling mode.
2. Press the SLEEP button(24).
ð The arrow of the SLEEP indication(27) appears on the
remote control.
3. In order to switch the night mode off, press the SLEEP
button(24) once again.
ð The arrow of the SLEEP indication(27) disappears.
ð The selected operating mode remains active.
Key lock (remote control only)
The function can be activated via the remote control both during
operation and in standby mode.
The key lock applies to the remote control only – the control
panel at the device is not affected and can be used nonetheless.
1. Simultaneously press the plus/ minus buttons(18, 19) on
the remote control.
ð The key lock is activated. The remote control cannot
send signals to the device.
ð The arrow of the LOCK indication(28) can be seen on
the remote control's display(21).
2. Simultaneously press the plus/ minus buttons(18, 19)
once more.
ð The key lock is deactivated.
ð The arrow of the LOCK indication(28) on the remote
control's display(21) disappears.
Memory function
If you switch the device back on from standby mode, the
previously selected operating mode and fan stage are saved.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Empty the condensation tray if necessary.
If necessary, remove the condensation drain hose and any
residual fluid from it.
Clean the device according to the Maintenance chapter.