14 EN
local air conditioner PAC 2000 E
Error code Indication Fault Cause Remedy
F0 n. a.
Refrigerant
leakage
protection
The inside of the device is heavily contaminated Contact Trotec
Air inlet or air outlet is blocked
Remove any foreign objects and
dirt from the air inlet and outlet.
Observe the minimum distances
specified in the technical data
Compressor malfunction: Temperature at the
housing is very high, compressor makes
unusual noises
Contact Trotec
The system is blocked on the inside Contact Trotec
Refrigerant leaks Contact Trotec
H3 n. a.
Compressor
overload
protection
The inside of the device is heavily contaminated Contact Trotec
Air inlet or air outlet is blocked
Remove any foreign objects and
dirt from the air inlet and outlet.
Observe the minimum distances
specified in the technical data
The fan does not run or runs too slowly Contact Trotec
Compressor malfunction: Temperature at the
housing is very high, compressor makes
unusual noises or refrigerant leaks
Contact Trotec
The system is blocked on the inside Contact Trotec
Pump does not operate or condensate cannot
be discharged
Contact Trotec
The rubber stopper at the condensate outlet is
not properly attached
Check the rubber stopper for tight
fit
Refrigerant leaks Contact Trotec
E8 n. a.
Overload
malfunction
The inside of the device is heavily contaminated Contact Trotec
Air inlet or air outlet is blocked
Remove any foreign objects and
dirt from the air inlet and outlet.
Observe the minimum distances
specified in the technical data
The fan does not run or runs too slowly Contact Trotec
Compressor malfunction: Temperature at the
housing is very high, compressor makes
unusual noises or refrigerant leaks
Contact Trotec
The system is blocked on the inside Contact Trotec
The temperature sensor on the mainboard
cannot determine temperature
Contact Trotec