6 EN
local air conditioner PAC 2000 E
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• Keep air inlets and outlets as well as the exhaust air hose
connection free.
• Make sure that no curtains or other objects interfere with
the air flow.
Prior to initial start-up, insert the batteries in the remote control.
Inserting the air filter
Note
Do not operate the device without an inserted air filter!
Without an air filter the inside of the device will be
heavily contaminated, which could reduce the
dehumidification performance and result in damage to
the device.
• Make sure that the air filters are installed before switching
the device on.
Connecting the condensation hose
The condensation drain hose serves as drip protection and, if
required, for discharging remaining condensate.
1. Remove the stopper from the condensate outlet(6).
2. Screw down the retaining clip for the condensation drain
hose.
3. Attach the sealed condensation drain hose to the
condensate outlet(6) and put the hose into the retaining
clip.