EN 11
air cooler PAE 49 / PAE 50
Permanent water connection
If you use the device for an extended period of time or you do
not want to fill the water tank all the time, you can connect a
permanent water connection hose to the hose connection(12).
Note
Once you have disassembled the supplied hose into its
individual components, this hose must no longer be
used.
Please observe the water inlet pressure ranging
between 0.1MPa (min.) and 0.4MPa (max.). The water
temperature should be below 25°C.
ü The device is switched off and disconnected from the
mains.
ü When filling the water tank with drinking water, please pay
attention to the filling level indication at the front of the
device. The water must not exceed the maximum filling
level.
1. Open the hose connection cover(12).
2. Connect the supplied permanent water connection hose to
the hose connection(12). Pay attention to the correct
direction of connection.
3. Guide the other hose end to a suitable water connection.
The permanent water connection hose must not be kinked.
Connecting the power cable
• Insert the mains plug into a properly secured mains
socket.
Info
When connecting the power cable, an acoustic signal
is emitted and the LEDs on the control panel briefly
light up in red or white. The On / OffLED(23) will then
be permanently illuminated in red in standby mode.