NORMAL.DOT Gespeichert in:G:\Support\Dokumentationen_CDs\8003Speedy\Service Manual\Servicemanual 8003.doc Gespeichert am:2003/03/10
max Version 14
Seite 23 von 87
I N D I V I D U A L M A R K I N G S Y S T E M S
Measuring the laser power:
To measure the laser power you need:
1. Laser protective goggles
2. Laser power meter
3. Interlock defeat tool
tools for measuring the laser power
CAUTION To make sure that there is no laser emission out of a
controlled area establish a limited access area by using non flamable
beam blocking curtains, temporary walls or other enclosures.
CAUTION The laser power measurement may only be performed by
service technichians that have been trained by Trotec and are familiar with
the hazards from lasers
CAUTION
Never expose any part of your body to the beam as this could result in
serious injuries.
CAUTION
To do the laser power measurement it is absolutely necessary to wear
laser protection glasses.