10 EN
fan heater TFC 19 E / TFC 20 E
The fan is not running:
Check whether the device is switched on.
Check the power connection.
Check the power cable and mains plug for damages.
The fan motor might be defective. Have a defective fan
motor replaced by a specialist electrical company.
The air current is reduced:
Check the air inlet and outlet. Make sure that air inlet and
outlet are not obstructed. Remove any dirt. Observe the
minimum distance from walls or other objects according to
the technical data.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright
position.
Note
Wait for at least 3minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Technical annex
Technical data
Parameter Value
Model TFC 19 E TFC 20 E
Heating capacity
level1:
level2:
1200W
2000W
1000W
2000W
Operating range -5 °C to +25 °C -10°C to +25°C
Mains connection 220 – 240 V/ 50Hz
Max. power
consumption
2000 W
Nominal current
consumption
8.7 A 8.6 A
Fusing 10 A 10 A
Plug type CEE 7/17
Protection class
II/
Type of protection IPX0 IP20
Cable length 1.5 m 1.5 m
Sound pressure level
(at a distance of 1m)
54 dB(A) 48 dB(A)
Overheating
protection
85 °C 65 °C
Dimensions (depthx
widthx height)
186x 186x
440mm
200 x 200x
520mm
Minimum distance to
walls and other
objects
A: top:
B: rear:
C: side:
D: front:
100 cm
100 cm
100 cm
100 cm
Weight 2 kg 2.5 kg