REMOVE COVER MAKE POWER CONNECTION
Step 3
A. Set unit in its final location. Be sure there is adequate
ventilation in your room. Under extreme heat
conditions, (100°F+, 38°C+), you may want to install an
exhaust fan.
Warning
Warranty is void if ventilation is insufficient.
B. Proper leveling of your True cooler is critical to
operating success (for non-mobile models). Effective
condensate removal and door operation will be effected
by leveling.
C. The cooler should be leveled front to back and side
to side with a level.
D. Ensure that the drain hose or hoses are positioned in
the pan.
E. Free plug and cord from inside the lower rear of the
cooler (do not plug in).
F. The unit should be placed close enough to the
electrical supply so that extension cords are never used.
Warning
Compressor warranties are void if the unit is more
than 7 ft. (2.1m) from plug-in connection.
LEVELING
Step 2
A. Place packing material behind cabinet as a
cushion. Carefully lay the unit on its back to
remove skid.
When lifting unit remember to
leave the cabinet upright for 24 hours before
plugging into power source.
B. Remove skid by unscrewing all base rail anchor
brackets. Place skid to the side.
C. Carefully lift cabinet upright.
LOCATING
Removing
skid from
bottom of
cabinet.
Leg levelers are height
adjustable by tightening or
loosen the leg lever.
REMOTE UNITS (This section
applies to remotes only!)
Remote cabinets must be ordered as remote. We do
not recommend converting from a standard self
contained to remote system.
All remote cabinets must be hard wired.
No castors available.
All remote cabinets come standard using 404A
refrigerant.
All remote units come standard with expansion valve,
liquid line solenoid, heated condensate pan, and
defrost timer when applicable.
Contact True Technical Service for BTU requirements.
No wiring necessary between cabinet and
condensing unit.
All remote condensing units purchased from
True are 208/230 volts single phase.
If you have any questions regarding this section,
please call True at 1-(800)-325-6152.
Some units have a
polyester strap that
secures the cabinet to
the shipping skid. Cut
this polyester strap
and remove the
wood skid.
Polyester Strap

Other manuals for True GDM-10F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the True GDM-10F and is the answer not in the manual?

True GDM-10F Specifications

General IconGeneral
BrandTrue
ModelGDM-10F
CategoryFreezer
LanguageEnglish

Related product manuals