EasyManuals Logo

True SPEC Series User Manual

True SPEC Series
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
20
TRUE
SPEC SERIES®: STR, STA & STG, ROLL-IN AND ROLL-THROUGH
www.truemfg.com
20
CHANGING “DEFROST INTERVALS”:
May need to unlock control.
This can only be changed if defrost mode parameter “DFM” is set for “TIM”.
WHY: The defrost interval is the time duration between defrost cycles. The defrost
interval time starts when the cabinet is supplied power or after a manual defrost.
1a
1c
1b
2
3
4
HOW TO CHANGE “DEFROST INTERVALS":
STEP 1 - To see the set point, press and hold the Info button and the
Stand-by button at the same time.
NOTE: Depending on the version of control, one of three parameters will
appear: “ScL image 1a, “SPL image 1b, “MdL image 1c.
STEP 2 - Push the Up button until “dFt” appears. See image 2.
STEP 3 - Press and hold the Info button to see the defrost interval
time. See image 3.
STEP 4 - While pressing and holding the Info button , press the
Up or Down button to change the defrost interval times (higher
the number the less frequent the cabinet will defrost).
STEP 5 - Once the defrost interval time has been changed, release the Info
button .
STEP 6 - Wait 30 seconds for the display to show temperature.
See image 4.
LAE Control
Manual Activation
Up Button
Info / Set Point
Button
Stand-By
Button
Manual Defrost /
Down Button

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the True SPEC Series and is the answer not in the manual?

True SPEC Series Specifications

General IconGeneral
CapacityVaries by model
Door BinsVaries by model
Freezer ShelvesVaries by model
Dimensions (H x W x D)Varies by model
WeightVaries by model

Related product manuals