EasyManua.ls Logo

TrueTime 151-602 - User Manual

Default Icon
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
(217) 352-9330 | sales@artisantg.com | artisantg.com
-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your
definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
Critical
and
expedited
services
Leasing
/
Rentals/
Demos
In
stock/
Ready-to-ship
!TAR-certified
secure
asset
solutions
Expert
team
I
Trust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Microsemi / Symmetricom / TrueTime 142-400-50 at our website: Click HERE

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the TrueTime 151-602 and is the answer not in the manual?

Summary

SECTION I GENERAL INFORMATION

1-1 INTRODUCTION

Provides an overview of the XL-DC Time and Frequency Receiver and its capabilities.

1-2 LIMITED WARRANTY

Details the manufacturer's warranty terms, conditions, and limitations for the product.

1-3 LIMITATION OF LIABILITY

Outlines the legal limitations of liability for damages incurred by the product's use.

1-4 PROPRIETARY NOTICE

States the confidential and proprietary nature of the document and its contents.

1-10 PHYSICAL SPECIFICATIONS

Lists the physical dimensions, weight, and mounting details of the XL-DC receiver and accessories.

1-11 ENVIRONMENTAL SPECIFICATIONS

Details the operating and storage temperature, and humidity limits for the unit.

1-12 POWER INPUT SPECIFICATIONS

Specifies the AC and DC power requirements and consumption for the XL-DC receiver.

1-13 BATTERY SPECIFICATIONS

Describes the type, life, and usage of the internal battery for memory backup.

1-14 TIMING;FREQUENCY PERFORMANCE SPECIFICATIONS

Defines the accuracy and stability performance for timing and frequency outputs.

1-15 INTERFACE SPECIFICATIONS

Details the serial data port specifications, including data rates, bits, and protocols.

1-20 INPUTS AND OUTPUTS

Lists the available input and output signals and their connection methods via BNC connectors.

1-60 SERIAL INTERFACE

Explains the connection and general format for the serial port interface.

SECTION II INSTALLATION

2-1 OVERVIEW

Provides a general overview of the XL-DC receiver, antenna unit, and cable components.

2-2 PROCEDURE

Outlines the step-by-step process for installing the XL-DC receiver and connecting components.

2-3 SPECIAL CONSIDERATIONS FOR EXTERNAL OSCILLATOR CONTROL OPTION

Provides guidance on interconnecting the XL-DC with an external oscillator for optimal performance.

2-4 RACK MOUNTING

Describes the procedure for mounting the XL-DC unit into a standard 19-inch rack system.

SECTION III OPERATION AND KEYPAD FUNCTION

3-1 INTRODUCTION

Introduces the section on operating the XL-DC receiver and understanding its keypad functions.

3-2 GENERAL OPERATION

Explains the general operational principles, including keypad and serial interface usage.

3-3 XL-DC START-UP

Details the initial messages and displays shown during the XL-DC receiver's power-up sequence.

3-4 SATELLITE ACQUISITION

Describes the process and factors affecting satellite signal acquisition for time synchronization.

3-10 OPERATIONAL MODES

Explains the three primary operational modes: AUTO, SURVEY, and TIME.

3-11 AUTO MODE

Details the AUTO mode for a simplified GPS receiver start-up and installation process.

3-12 SURVEY MODE

Describes the SURVEY mode for dynamic or pseudo-static platform applications.

3-13 TIME MODE

Explains the TIME mode for accurate, averaged position-based timing solutions.

3-20 TIME QUALITY INDICATION

Describes how time quality is indicated and the thresholds used for error reporting.

3-27 KEYPAD OPERATION

Covers the basic operation of the 16-key keypad for entering functions and data.

3-28 SELECTING FUNCTIONS AND ENTERING DATA

Provides rules and guidelines for selecting and entering data for keypad functions.

3-29 KEYPAD FUNCTION LIST

Lists all available keypad functions, their descriptions, and default power-up states.

3-100 KEYPAD FUNCTION 00 - KEYPAD HELP FUNCTION

Explains how to use Keypad Function 00 to get descriptions of all available keypad functions.

3-101 KEYPAD FUNCTION 01 - TIME ZONE ENTRY;REQUEST

Details how to set or request the time zone offset for the receiver.

3-104 KEYPAD FUNCTION 04 - SERIAL PORT SETUP

Describes how to configure the serial port parameters like baud rate and data bits.

3-105 KEYPAD FUNCTION 05 - TIME QUALITY ENABLE;SETUP

Explains how to enable/disable time quality indicators and set error thresholds.

3-106 KEYPAD FUNCTION 06 - KEYPAD LOCKOUT ENABLE

Covers enabling or disabling the keypad lockout feature to prevent accidental entries.

3-107 KEYPAD FUNCTION 07 - EXTERNAL OSCILLATOR ENABLE (OPTION)

Details how to enable or disable phase locking to an external oscillator.

3-113 KEYPAD FUNCTION 13 - WORST-CASE TIME ERROR REQUEST

Explains how to request the worst-case time error during periods without satellite tracking.

3-114 KEYPAD FUNCTION 14 - EXTERNAL OSCILLATOR PARAMETER ENTRY;REQUEST (OPTION)

Describes how to set parameters for an external oscillator used for disciplining.

3-116 KEYPAD FUNCTION 16 - EMULATION MODE ENABLE

Explains how to enable or disable emulation mode for compatibility with older systems.

3-116.1 SERIAL PORT EMULATION COMMANDS

Lists the serial port commands available when emulation mode is enabled.

3-116.2 MODE C - CONTINUOUS TIME, ONCE PER SECOND

Details how to set the serial port to output time messages once per second.

3-116.3 MODE F - FORMAT THE TIME MESSAGE

Explains how to alter the format of the time output string for serial functions.

3-117 KEYPAD FUNCTION 17 - SLOW CODE SETUP (OPTION)

Describes how to control the slow code output pulse widths.

3-118 KEYPAD FUNCTION 18 - SOFTWARE VERSION REQUEST

Explains how to obtain information about the installed system and GPS-XL software versions.

3-128 KEYPAD FUNCTION 28 - TIME INTERVAL;EVENT TIMING INPUT (OPTION)

Details how to measure time intervals or event timing relative to the XL-DC time.

3-129 KEYPAD FUNCTION 29 - FREQUENCY MEASUREMENT INPUT (OPTION)

Explains how to set up and perform frequency offset measurements.

3-150 KEYPAD FUNCTION 50 - POSITION ENTRY;REQUEST

Covers entering or requesting the current antenna position for initialization.

3-151 KEYPAD FUNCTION 51 - ANTENNA CABLE DELAY ENTRY;REQUEST

Describes how to enter or request antenna cable delay compensation.

3-152 KEYPAD FUNCTION 52 - DISTRIBUTION CABLE DELAY ENTRY;REQUEST

Explains how to enter or request distribution cable delay compensation.

3-153 KEYPAD FUNCTION 53 - OPERATIONAL MODE ENTRY;REQUEST

Details how to select the operating mode (AUTO, SURVEY, TIME).

3-155 KEYPAD FUNCTION 55 - ALTITUDE UNITS ENTRY;REQUEST

Covers selecting units for altitude display (feet or meters).

3-156 KEYPAD FUNCTION 56 - AVERAGE POSITION ENTRY;REQUEST

Explains how to enter or request the accurate, averaged antenna position.

3-160 KEYPAD FUNCTION 60 - SATELLITES LIST REQUEST

Describes how to list tracked or bad satellites and their signal strengths.

3-165 KEYPAD FUNCTION 65 - SATELLITE SELECT

Details how to select or deselect specific satellites for the receiver to track.

3-166 KEYPAD FUNCTION 66 - DAYLIGHT SAVING ENABLE

Explains how to enable or set entry/exit times for Daylight Saving Time.

3-168 KEYPAD FUNCTION 68 - YEAR ENTRY (GPS EPOCH MANAGEMENT)

Covers manually entering the year via serial for calendar calculations.

3-169 KEYPAD FUNCTION 69 - SELECT LOCAL;STANDARD;GPS;UTC TIME

Describes selecting the displayed and output time type (LOCAL, STD, GPS, UTC).

3-171 KEYPAD FUNCTION 71 - OSCILLATOR STATISTICS REQUEST

Explains how to request oscillator phase, frequency offset, drift rate, and DAC value.

3-172 KEYPAD FUNCTION 72 - FAULT STATUS REQUEST

Details how to display the status of various fault detectors within the XL-DC.

3-173 KEYPAD FUNCTION 73 - REQUEST;SET ALARM STATUS;CONTROL

Covers controlling and monitoring alarm/fault conditions and their contribution to outputs.

3-179 KEYPAD FUNCTION 79 - WARM START

Describes how to issue a reset command to the GPS core module for a warm start.

SERIAL FUNCTIONS

3-197 GENERAL SERIAL INPUT AND OUTPUT FORMAT

Explains the general format for serial commands and data strings exchanged with the unit.

3-198 SERIAL ERROR MESSAGES

Lists common error messages returned by the serial port and their meanings.

3-199 SERIAL FUNCTION LIST

Provides a comprehensive list of all available serial functions and their parameters.

3-201 SERIAL FUNCTION F01 - TIME ZONE ENTRY;REQUEST

Details how to set or request the time zone offset via serial commands.

3-202 SERIAL FUNCTION F02 - 12;24 HOUR FORMAT ENTRY;REQUEST

Explains how to set or request the time display format (12-hour or 24-hour).

3-203 SERIAL FUNCTION F03 - TIME;DATE ENTRY;REQUEST

Covers entering or requesting the current time and date via serial commands.

3-205 SERIAL FUNCTION F05 - TIME QUALITY ENABLE;SETUP

Details enabling/disabling time quality indicators and setting error thresholds via serial.

3-206 SERIAL FUNCTION F06 - KEYPAD LOCKOUT ENABLE

Explains how to enable/disable keypad lockout via serial commands.

3-207 SERIAL FUNCTION F07 - EXTERNAL OSCILLATOR ENABLE (OPTION)

Details how to enable or disable external oscillator phase locking via serial.

3-208 SERIAL FUNCTION F08 - CONTINUOUS TIME ONCE PER SECOND ENABLE

Describes enabling continuous time output once per second via serial.

3-209 SERIAL FUNCTION F09 - TIME ON REQUEST ENABLE

Explains how to enable time-of-day string output upon request via serial.

3-211 SERIAL FUNCTION F11 - TIME OUTPUT FORMAT ENTRY;REQUEST

Details how to request or enter the time output string format via serial.

3-213 SERIAL FUNCTION F13 - WORST-CASE TIME ERROR REQUEST

Explains how to request the estimated worst-case time error via serial.

3-214 SERIAL FUNCTION F14 - EXTERNAL OSCILLATOR PARAMETER ENTRY;REQUEST (OPTION)

Describes setting external oscillator parameters via serial commands.

3-215 SERIAL FUNCTION F15 - EXCLUSIVE USE ENABLE

Explains how to enable or disable exclusive use of serial or IEEE ports via serial.

3-217 SERIAL FUNCTION F17 - SLOW CODE SETUP (OPTION)

Details how to set pulse widths for the optional slow code output via serial.

3-218 SERIAL FUNCTION F18 - SOFTWARE VERSION REQUEST

Explains how to request software version information via serial.

3-226 SERIAL FUNCTION F26 - PROGRAMMABLE PULSE OUTPUT (OPTION)

Describes setting parameters for the programmable pulse output via serial.

3-228 SERIAL FUNCTION F28 - TIME INTERVAL;EVENT TIMING INPUT (OPTION)

Details how to request time interval or event times via serial.

3-229 SERIAL FUNCTION F29 - FREQUENCY MEASUREMENT INPUT (OPTION)

Explains how to set up and perform frequency measurements via serial.

3-250 SERIAL FUNCTION F50 - POSITION ENTRY;REQUEST

Covers entering or requesting antenna position via serial commands.

3-251 SERIAL FUNCTION F51 - ANTENNA CABLE DELAY ENTRY;REQUEST

Describes setting antenna cable delay compensation via serial.

3-252 SERIAL FUNCTION F52 - DISTRIBUTION CABLE DELAY ENTRY;REQUEST

Explains setting distribution cable delay compensation via serial.

3-253 SERIAL FUNCTION F53 - OPERATIONAL MODE ENTRY;REQUEST

Details how to select operating modes via serial commands.

3-255 SERIAL FUNCTION F55 - ALTITUDE UNITS ENTRY;REQUEST

Covers selecting altitude units (feet/meters) via serial.

3-256 SERIAL FUNCTION F56 - AVERAGE POSITION ENTRY;REQUEST

Explains entering or requesting the average position via serial.

3-260 SERIAL FUNCTION F60 - SATELLITES LIST REQUEST

Describes requesting a list of satellites via serial.

3-265 SERIAL FUNCTION F65 - SATELLITE SELECT

Details selecting or deselecting satellites via serial commands.

3-266 SERIAL FUNCTION F66 - DAYLIGHT SAVING ENABLE

Explains setting DST entry/exit times via serial.

3-268 SERIAL FUNCTION F68 - YEAR ENTRY (GPS EPOCH MANAGEMENT)

Covers manually entering the year via serial for calendar calculations.

3-269 SERIAL FUNCTION F69 - SELECT LOCAL;STANDARD;GPS;UTC TIME

Describes selecting the time type (LOCAL, STD, GPS, UTC) via serial.

3-271 SERIAL FUNCTION F71 - OSCILLATOR STATISTICS REQUEST

Explains requesting oscillator statistics via serial.

3-272 SERIAL FUNCTION F72 - FAULT STATUS REQUEST

Details requesting fault status via serial commands.

3-273 SERIAL FUNCTION F73 - REQUEST;SET ALARM STATUS;CONTROL

Covers controlling and monitoring alarms/faults via serial commands.

3-279 SERIAL FUNCTION F79 - WARM START

Describes initiating a warm start via serial command.

SECTION VIII IRIG B, IRIG H (OPTION) AND IRIG E (OPTION) TIME CODE FORMAT

8-1 INTRODUCTION

Introduces the IRIG standard time codes and their applications.

8-2 IRIG CODE FORMAT

Describes the structure and segments of IRIG B, H, and E time codes.

8-3 EMBEDDED WORST-CASE TIME ERROR FLAGS

Explains the time error flags encoded within the IRIG B code's control segment.

8-10 SPECIAL IRIG B TIME CODE FORMAT (EMBEDDED GPS DATA OPTION)

Details the special IRIG B format that embeds GPS data and time error flags.

TrueTime 151-602 Specifications

General IconGeneral
Update Rate1 Hz
Operating Temperature-40 to 85°C
Output Frequency10 MHz
ProtocolsNMEA
Output Signal1 PPS

Related product manuals