enables the LED to blink under the conditions given above. The response is: OK<CR><LF>
if successful.
Sending: F73<SP>BLINK DISABLE<CR>
disables the LED from blinking in all but the processor reset mode as given above.
Minor Alarm conditions may be delayed if power-on Minor Alarm SUPPRESS is set to a value (in
seconds). The Minor Alarms will be suppressed until either the unit power-on time exceeds the Minor
Alarm suppress time or the unit locks to GPS.
The power-on Minor Alarm suppress time can be read by the following command:
F73<SP>SUPPRESS<CR>
which returns:
F73<SP>POWER-ON<SP>MINOR<SP>ALARM<SP>SUPPRESS<SP><seconds><SP>s<CR><LF>
where:
F = Ascii character F
73 = function number
<seconds> = seconds from 0 to 86400
<SP> = Ascii space character
<CR> = Carriage Return
<LF> = Line Feed
The Minor Alarm suppression power-on timeout can be set by the following command:
F73<SP>SUPPRESS<SP><seconds><CR>
The seconds can be set to any value from 0 to 86400 which sets the suppress time and returns:
OK<CR><LF>
if successful.
3-274 through 3-278 reserved
3-279 SERIAL FUNCTION F79 - WARM START
This function issues a reset command to the Trimble SVeeSix GPS core module. It does not clear
stored almanac and ephemeris data which are retained in battery-backed RAM.