3 = 'E' Oscillator Tuning Voltage Alarm Enabled
'D' Oscillator Tuning Voltage Alarm Disabled
4 = 'E' Non-Volatile RAM Battery Voltage Alarm Enabled
'D' Non-Volatile RAM Battery Voltage Disabled
5 = 'E' Initial Acquisition Mode Alarm Enabled
'D' Initial Acquisition Mode Alarm Disabled
6 = '-' Currently not used
7 = '-' Currently not used
8 = '-' Currently not used
The command returns: OK<CR><LF>
if successful.
The time error threshold at which the time error fault is activated can be queried or set by the following
command.
Sending:
F73<SP>THRESHOLD<CR>
returns: F73<SP>THRESHOLD<SP><nanoseconds><SP>ns<CR><LF>
where <nanoseconds> is the time error threshold in nsec.
Sending: F73<SP>THRESHOLD<SP><nanoseconds><CR>
sets the time error threshold and returns: OK<CR><LF>
if successful.
The timeout after which a time error fault becomes a timeout fault can be queried or set by the following
command.
F73<SP>TIMEOUT<CR>
which returns: F73<SP>TIMEOUT<SP><seconds><SP>s<CR><LF>
where <seconds> is the timeout in seconds, between 0 and 86400.
Sending: F73<SP>TIMEOUT<SP><seconds><CR>
sets the timeout and returns: OK<CR><LF>
if successful.