EasyManua.ls Logo

Truma BGEA 14 - Technical Data and Warranty; Technical Specifications

Truma BGEA 14
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
Technical data
Manufacturer
Truma Gerätetechnik GmbH & Co. KG
P.O. Box 1252
85637 Putzbrunn / Munich
Germany
Protection type
IP21
Water capacity
14 litres
Water pressure
max. 400 kPa
Type of gas
LPG (Propane)
Test point pressure
2.75 kPa
Nominal input
4.7 MJ/h
Heat output
4.1 MJ/h
Gas consumption
90 g/h
Injector size
0.70 mm
Heating up time from approx. 20 °C up to approx. 65 °C
(14 litres)
Gas operation: approx. 45 min.
Electrical operation: approx. 40 min.
Gas and electrical operation: approx. 28 min.
Power consumption 12 V
Ignition: 0.160 A
Heating up: 0.12 A
Stand-by: 0.05 A
Power consumption 230 V ~ / 240 V ~
Heating up: 5.7 A / 5.9 A, 1300 W / 1415 W
Weight (empty) 14 litres
7.5 kg (BGA 14)
7.9 kg (BGEA 14)
AGA Approval-No
5801
5375
The right to make technical modifications is reserved!
Dimensions
F
cut out
245
129
324
168
47
30
109
24
Fig. 7
water
connections
gas connection
with test point
electronic
cowl
cut out
360
347
383
92
Fig. 8
All dimensions in mm.