www.deluxegroup.co.nz
In Germany, only pressure regulating equipment that complies with DIN EN 16129 (in vehicles)
with a fixed output pressure of 30 mbar may be used for the gas system. The flow rate of the
pressure regulating equipment must correspond to at least the maximum consumption of all devices
installed by the system manufacturer.
We recommend the Truma MonoControl CS gas pressure regulation system for vehicles and the
Truma DuoComfort / DuoControl CS gas pressure regulation system for dual-cylinder gas systems.
At temperatures of around 0 °C and below, the gas pressure regulation system or the changeover
valve should be operated with the EisEx regulator heater.
Suitable hoses that meet national regulations must always be used in the
respective country for which the equipment is destined.
Ensure that the inside of the vehicle is sufficiently ventilated. When the unit is
started up, there may be some smoke and/or smell due to dust or dirt. Especially if it has
not been used for a long time.
This appliance can be used by children aged 8 and over, as well as by persons with reduced
physical, sensory or mental capabilities or with a lack of experience and knowledge, provided that
they are supervised or have been instructed on how to use the appliance safely and that they
understand the resulting risks. Children must not be allowed to play with the appliance.
The integrity and tight fit of the exhaust double duct must be checked regularly, particularly at the
end of long trips. Also check the mounting of the unit and the cowl.
Operation while driving
Directive UN ECE R 122 stipulates that a safety shut-off device is required if motor homes and
caravans are heated while driving. The Truma MonoControl CS gas pressure regulation system
satisfies this requirement. Throughout Europe, a type-tested liquefied gas heating system may be
used while driving (according to the directive UN ECE R 122) if the system includes a gas pressure
regulator with an appropriately configured gas installation. National regulations and rules must be
followed.
If no safety shut-off device (e.g. as contained within the Truma MonoControl CS gas pressure
regulation system) has been installed, the gas cylinder must be closed when driving and information
signs must be attached in the gas cylinder protection box and in the vicinity of the control panel.
Liquid gas equipment must not be used when refuelling, in multi-storey car parks, in garages or on
ferries.
To prevent damage to the appliance from spray water, such as when cleaning the vehicle, do not
spray water directly into the cowl.
Troubleshooting
If you notice unusual noises or smells, close off the gas supply and switch off the Combi.