– or gas and electrical mode
– mixed mode Only possible in winter.
Heating and hot water mode
In heating and hot water mode, the unit automatically selects the required
operating level according to the temperature difference between the temperature
set on the control panel and the current room temperature. If the boiler has been filled, the
water is automatically heated as well. The water temperature depends on the selected operating
mode and the heater output.
All 3 energy selection options can be used for winter deployment.
– In gas mode the unit automatically selects the operating level that is required.
– In electrical mode output of 900 W (3.9 A) or 1800 W (7.8 A) can be manually preselected in
accordance with the fuse protection at the camp site. If more output is required (e.g. heating up or
low outside temperatures) gas or mixed mode should be selected so that enough heating power is
always available.
– In mixed mode 230 V electrical mode is preferred if the power requirement is low (e.g. for
maintaining the room temperature). The gas burner is not enabled until the power requirement is
higher, and is the first to switch off during heat-up operations.
Hot water mode (with filled boiler only)
Gas mode or 230 V electrical mode is used to generate hot water. The water temperature can be set
to 40 °C or 60 °C.
– In gas mode the water is heated at the lowest burner setting. Once the water temperature has
been reached, the burner switches off.
– In electrical mode output of 900 W (3.9 A) or 1800 W (7.8 A) can be manually selected in
accordance with the fuse protection at the camp site.
Mixed mode is not possible. With this setting the unit automatically selects electrical mode. The gas
burner is not enabled.