Operating instructions
To be kept in the vehicle.
This document is part of the product.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or prop-
erty damage.
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Evacuate all persons from the vehicle.
Shut off the gas supply at the gas contain-
er or source.
Do not touch any electrical switch or use
any phone or radio in the vehicle.
Do not start the vehicle’s engine or electric
generator.
Contact the nearest gas supplier or certi-
fied service technician for repairs.
If you cannot reach a gas supplier or certi-
fied service technician, contact the nearest
fire department.
Do not turn on the gas supply until gas
leaks have been repaired.
Installation and service must be performed
by a certified service technician, service
agency, or the gas supplier.
LP gas furnace with supplementary
indirect water heating
Conforms to ANSI Std. Z21.47
Certified to CSA 2.3
4010007
Truma Combi

Table of Contents

Other manuals for Truma Combi eco plus

Questions and Answers

  • K
    Kimberly GuzmanAug 14, 2025
    How to fix slow water heating in Truma Combi eco plus Furnace?
    • W
      wconwayAug 14, 2025
      Water heating slowly in your Truma Furnace may be caused by lime scale (hard water calcification) in the water container. Decalcify the water container.
  • D
    Danielle BeckAug 18, 2025
    Why is water dripping from the Truma Furnace pressure relief/drain valve?
    • M
      munozwilliamAug 18, 2025
      Water may drip or flow from the drainage socket of the pressure relief/drain valve for several reasons. It could be due to excessive water pressure in the system, which can be resolved by checking and adjusting the pump pressure or replacing the water pump. If a Truma pressure relief/drain valve is installed, it might be releasing pressure above 65.25 psi (4.5 bar), which is a protective function and not a fault; if this continues, contact Truma service. Other potential causes include excessive water pressure requiring replacement of the water pressure reducer by a qualified technician, or lime/dirt under the valve seat, which can be addressed by rinsing the valve.
  • S
    scoleAug 21, 2025
    What to do if the Truma Combi eco plus Furnace water container cannot be emptied?
    • L
      Larry DavilaAug 21, 2025
      If the water container cannot be emptied even when the pressure relief/drain valve is open, it is likely that the drainage socket is obstructed. Clear any obstructions such as slush, ice, or leaves from the opening of the drainage socket. Ensure that the faucets are opened to the 'hot' position.
  • M
    mreedAug 25, 2025
    Why does water drain or the hot water container of Truma Combi eco plus Furnace cannot be refilled?
    • J
      Jordan NolanAug 25, 2025
      If water drains or the hot water container cannot be refilled, the pressure relief/drain valve is likely open. To resolve this, close the pressure relief/drain valve.
  • T
    Tracy BoydAug 28, 2025
    How to fix slow water heating in my Truma Combi eco plus?
    • J
      jamiewuAug 28, 2025
      If the water heats up too slowly, it might be due to lime scale in the water container. You should descale the water container. Refer to “Decalcifying and cleaning the water container” on page 17.
  • G
    Greg GibsonAug 31, 2025
    What to do if water escaping at Truma Combi eco plus Furnace pressure relief/drain valve?
    • J
      Jennifer BurnsAug 31, 2025
      If water is escaping at the pressure relief/drain valve, it could be due to high water pressure in the system or contamination under the valve seat. A qualified technician should install a water pressure regulator at the fresh water supply. Also, try rinsing the pressure relief/drain valve to remove any lime or dirt from the valve seat. If the issue persists, a qualified technician should replace the pressure relief/drain valve.
  • A
    Amy DavidsonSep 4, 2025
    Why is water draining from my Truma Furnace and the hot water container cannot be refilled?
    • J
      Jeffrey ColemanSep 4, 2025
      If water is draining and the hot water container cannot be refilled, the pressure relief/drain valve is likely open. Ensure that you close the pressure relief/drain valve.
  • R
    Randy LoweSep 6, 2025
    What to do if the Truma Furnace water container cannot be emptied even though the pressure relief/drain valve is open?
    • H
      hgomezSep 6, 2025
      If the water container won't empty even with the pressure relief/drain valve open, the drainage socket of the valve might be obstructed. Remove any obstructions like slush, ice, or leaves from the drainage socket opening, and ensure that the faucets are opened to the 'hot' position.
  • B
    Beth TrevinoSep 10, 2025
    Why is water slowly dripping from the Truma Combi eco plus Furnace pressure relief/drain valve?
    • J
      John HoffmanSep 10, 2025
      Slow dripping from the pressure relief/drain valve indicates that the pressure inside the water container is rising above approximately 65.25 psi (4.5 bar). The Truma pressure relief/drain valve is designed to protect the water container against pressure exceeding this level. This is not a fault.

Summary

Consumer Safety Information

Safe handling of malfunctions

Instructions for dealing with appliance malfunctions and potential hazards.

Safe maintenance and repair

Emphasizes professional servicing and avoiding unauthorized repairs.

Operating Instructions

Starting the Combi furnace

Provides essential warnings and steps for safely starting the Combi furnace.

Filling the water container

Procedures and precautions for filling the furnace's water container.

Switching on the furnace

Details the steps required to power on and operate the Combi furnace.

Shutdown

Draining the water container

Instructions for draining the water container to prevent freezing damage.

Combi Technical Data

Maintenance and service

Truma pressure relief;drain valve

Details manual operation and inspection of the pressure relief/drain valve.

Troubleshooting

Truma Combi eco plus Specifications

General IconGeneral
Fuel TypePropane / butane
Power Supply230 V ~ 50 Hz / 12 V
Water heating time (from approx. 15 °C to approx. 60 °C)approx. 20 min.
Weight14.5 kg
Efficiency (Diesel Mode)Not applicable
IgnitionElectronic
ControlDigital
Quiescent current consumption0.0013 A