15
Combi Technical Data
Fuel LP gas (propane only)
Inlet pressure 11–13in. wc (27.4–32.4mbar)
Manifold pressure 10 in. wc (24.9mbar)
Duct static pressure minimum of 0.00in. wc (0.0mbar)
maximum of 0.65in. wc (1.6mbar)
Temperature rise <150°F (83°C)
Energy Input Rate / Gas Consumption
LP gas mode Operating level 1 Operating level 2 Operating level 3
Combi eco
Combi eco plus
7,500BTU/h (2.2kW)
5.3oz/h (150g/h)
14,300BTU/h (4.2kW)
10oz/h (290g/h)
–
Combi comfort
Combi comfort plus
7,500BTU/h (2.2kW)
5.3oz./h (150g/h)
14,300BTU/h (4.2kW)
10oz/h (290g/h)
20,400BTU/h (6kW)
14oz/h (410g/h)
Electric mode
Combi eco plus
Combi comfort plus
850W 1,700W –
Mixed mode LP gas + electric
Combi eco plus
(maximum)
7,500 BTU/h (2.2kW) + 1,700 W
Combi comfort plus
(maximum)
14,300 BTU/h (4.2kW) + 1,700 W
Power supply
Power consumption at 12 VDC (DC < 1Vpp)
Combi eco
Combi eco plus
transient: max. 6.1 A
(average power consumption: approx. 1.6 A)
Combi comfort
Combi comfort plus
transient: max. 6.1 A
(average power consumption: approx. 1.8 A)
Water heating only max. 0.9A
Power consumption at 120 VAC / 60Hz (mains connection or sine wave generator)
Operating level 1 Operating level 2 Operating level 3
Combi eco plus
Combi comfort plus
7.1A 14.2A –
Hot Water System
Capacity of water container 2.64 gallons (10 liters)
Water heating time from
59°F (15°C) to 140°F (60°C)
approx. 23 minutes in hot water mode (measured according to
EN15033)
Water inlet pressure max. 40.6psi (2.8bar)
System operating pressure max. 65.25psi (4.5bar)
Shipping weight (without water and without peripheral equipment)
Combi eco
Combi comfort
35.1 lbs.(15.9 kg)
Combi eco plus
Combi comfort plus
37.0 lbs.(16.8 kg)