EQUIPMENT DETAILS
113
Note: The Waeco fridge has an optimum
ambient temperature range of +16
O
c to
+32
O
c. Outside this range the efficiency of
the unit may be affected to the point where
the unit may not cool the foodstuffs inside.
Switching off and storing the refrigerator
If you do not intend to use the refrigerator for
a long time, proceed as follows:
Set the temperature control knob to level ‘0’.
Disconnect the power cable from the battery
or pull the AC cable plug out of the rectifier.
Clean the refrigerator.
Turn the locking wheel (4) anti-clockwise to
the end stop (‘Vent’).
Close the door until it latches in.
The door stays open thus preventing smells
from arising.
Replacing the interior light
If the interior light in the refrigerator is faulty,
you can change the bulb (12 V, 3 W).
Remove the cover.
Pull the light (5) out of the sheet metal straps.
Slide in the new lamp between the sheet
metal straps, until it snaps into place.
Change the fuse
(only DC/AC refrigerators).
If the fuse in the rectifier is faulty too, you can
replace this too.
Lever the fuse compartment (6) open with
a screwdriver.
Replace the fuse (250 V/3 A).
Close the fuse compartment again.