Always observe the operating instructions and the
“Safety instructions” prior to starting! The vehicle owner
is responsible for correct operation of the appliance.
Start-up
– Remove the cowl cover (Truma VarioHeat) (if present).
– Open the gas cylinder and the quick-acting valve.
– Establish the power supply (12V and 230V ).
– Select the operating mode and set the desired temperature.
Initial start-up
In order to perform the initial start-up, the following steps are
required:
– Switch on the power supply. 12 V for Truma CP plus
VarioHeat control panel and Truma VarioHeat. 230 V for
the Truma E-Kit and air conditioning systems.
– Start the search of the appliances under the menu item
“Service menu” -> “RESET” -> “PR SET”.
After confirmation, the Truma CP plus VarioHeat control panel
initialises itself. “INIT ..” appears on the display while this is in
progress. The appliances that have been found are stored in
the control panel.
Operation
The Truma E-Kit is operated via the Truma CP plus VarioHeat
control panel. Operation of the Truma E-Kit is described in
the operating instructions for the Truma CP plus VarioHeat
control panel.
Operating modes
Electrical operation (EL)
Only the Truma E-Kit is used for heating in electrical mode.
The ventilator of the Truma VarioHeat is used for warm air
distribution.
Depending on the ambient temperature, electrical heat-
ing power alone might not be sufficient to reach the
specified room temperature. Switch to mixed or gas mode to
increase the heating power.
EL1
In electrical mode EL1, the Truma E-Kit provides 900W of
heating power until the desired room temperature is reached.
EL2
In electrical mode EL2, the Truma E-Kit provides a maximum
of 1800W of heating power until the desired room tempera-
ture is reached.
Mixed mode (MIX)
In mixed mode, the Truma E-Kit is used together with the
Truma VarioHeat to provide heating.
This mode is the fastest way of reaching the specified
room temperature.
MIX1
In mixed mode MIX1, the Truma E-Kit provides 900W of
heating power in addition to the heating power of the Truma
VarioHeat.
MIX2
In mixed mode MIX2, the Truma E-Kit provides a maximum
of 1800W of heating power in addition to the heating power
of the Truma VarioHeat.
Operating instructions
Gas mode (GAS)
Only the Truma VarioHeat is used for heating in gas mode.
Technical data
Rated power at 230V
Level 1: 900W
Level 2: 1800W
Rated power at 12V
approx. 2W
Temperature range
-30°C to 50°C
Weight
2.2 kg
Protection type
IPX0B
Protection class
Class 1