27EN
8
6
Figure 3
Check for leaks (e.g in Germany in accordance with G 607).
If there is a gas system leak, close the cylinder valve, have the gas
system repaired by an expert immediately and do not open the
valve in the meantime.
Unscrew the pump from the test connection and screw the
screw cap (8) back onto the test connection.
It is essential to reattach the screw cap (8) every time after it has
been removed.
Reset the reset button.
To reset, press the reset button (6) firmly and turn it slightly anticlock-
wise. Ensure that the reset button (6) remains in the position “ready
for operation” (Figure2a).
The Torx T20(10) from the screw aid(9) can be used to assist
the turning movement.