11EN
The electrical heating rod is fitted with an excess tem-
perature cut-out. In the event of a fault, switch off at the
control panel, wait 5 minutes, then switch on again.
Using the water
The water temperature is mixed according to the position of
the pre-selecting mixing tap(s) or premixing valve. Make sure
that the water pump is switched off when you have finished
using the water.
Draining the Therme
If the mobile home is not used during periods of frost, it
is essential that the Therme be emptied!
1. Interrupt current for water pump (main switch or trans former).
2. Drain water from tank (or remove water pump from tank).
3. Open taps in kitchen and (or) bathroom and set pre-mixing
valve(s) – if available – to hot.
4. Turn draining and ventilating valves (4) to full extent to open.
In order to check the water that is flowing out, place an
appropriate container (capacity 5 litres) beneath the
drainage socket of the drain valve.
5. Check whether all the wa ter content (5 litres) has complete-
ly run out.
There shall be no guarantee claims for damage caused
by frost!
Maintenance
The device must be descaled on a regular basis (at least twice
a year).
We recommend using suitable commercially available prod-
ucts to clean, sterilise and maintain the Therme.
Products containing chlorine are not suitable.
Trouble-shooting list
Fault Cause Rectification
Not heating up. No operating
voltage.
Restore power
supply.
Taking an ex-
tremely long time
to heat up in
230 V operation
Heating element
furred.
Descale water
system (see
maintenance).
If this does not solve the problem, please contact the Truma
Service.