Wrinkle happens from label lower left to upper right direction
◼ Make sure the Printhead Pressure Adjustment Knob (green) is in correct position for the current media width. (1” to 2” or 3” to 4”)
◼ Turn the screw counterclockwise per level and print to see if the winkle has gone.
◼ If the ribbon tension adjustment knob has positioned on the level of outermost side but the ribbon winkle cannot be removed, please switch
the printhead pressure (green) at 1 level and print the label again to check if the wrinkle is gone.
◼ If the wrinkle can’t be avoided, please contact the Customer Service Department of your purchased reseller or distributor for service.