EasyManua.ls Logo

TTI PL154 - Specification

Default Icon
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specification
MAIN OUTPUT(S)
Output Range: Nominally 0-32V, (PL320/330); 0-15.5V (PL154).
Nominally 0-2·1A (PL320); 0-3·1A (PL330); 0-4A (PL154).
Output Voltage Setting: By coarse and fine controls; resolution <5mV across the range.
Output Current Setting: By single logarithmic control.
Output Mode: Constant voltage or constant current modes with automatic cross-over.
Decimal points flash to indicate constant current mode.
Configuration Selection:
(QMD and QMT only)
Isolated, True parallel, Series, or Series Tracking via front panel switches.
Output Switch: Isolates the output and permits voltage and current limits to be set up before
connecting the load.
Output Terminals: 4mm terminals on 19mm (0·75") spacing.
Sensing: Remote via 4mm terminals or direct via shorting links (provided).
Output Impedance:
Constant Voltage:
Constant Current:
<5 m at 1kHz.
Typically 50 kwith voltage limit at maximum.
Output Protection: Up to maximum output voltage +20 Volts forward; diode clamped for reverse
voltages and up to 3A reverse current.
Load & Line Regulation: < 0·01% of maximum output for 90% load change or 10% line change.
Ripple and Noise: Typically <1 mV rms.
Transient Response: < 20 µsec to within 50 mV of setting for 90% load change.
Temperature Coefficient: Typically < 100 ppm/
O
C.
Meter Type: Dual 3·75 digit (4095 count) with 12·5mm (0·5") LEDs. Reading rate 4Hz.
Meter Resolution: 10 mV and 1mA over the entire range.
Meter Accuracy: Voltage 0·1% of reading + 1 digit, current 0·3% of reading + 1 digit.
Current Meter Damping: ~20 ms, switchable to 2 sec for averaging of rapidly varying loads.
LOGIC OUTPUT (PL320QMT & PL330QMT)
Output Voltage Range: 4 to 6 Volts.
Output Current: 0·1 to 4 Amps (PL320QMT); 0·1 to 7 Amps (PL330QMT).
Output Switch: Electronic.
Output Terminals: 4mm terminals on 19mm (0·75") spacing.
Over-Voltage Protection: Above 7 Volts.
Output Protection: Clamped by the over-voltage protection circuit for forward voltages over
7 Volts and up to 1 Amp forward current. Diode clamped for reverse voltages
and up to 3 Amps reverse current.
Load & Line Regulation: < 0·01% of maximum output for 90% load change or 10% line change.
Ripple and Noise: Typically <1 mV rms.
2

Related product manuals