5.2 Technical Data
5.2.1 B-Fire 50 (round) (PIN: 0558CL1179)
Type
C11/C31
Gas type
G20
G20/G25
G25
G30/G31
G30/G31
G31
I2H,I2E,I2E+
I2ELL
I2L
I3B/P(30/50)
I3+
I3P(30,37,50)
Supply Pressure
mbar
20
20
25
30/50
28-30/37
30/37/50
Nominal Heat Input
Gross (Hs)
kW
12
12.0/9.8
11
9
9
8
Output
kW
7.5
6.8/5.5
6.9
5.6
5.6
5.0
Consumption
m³/hr
1.143
1.143/1.085
1.218
0.257
0.257
0.301
Burner Pressure (hot)
mbar
12.7
12.7
15.7
28.8
28.8
29.9
Injector Marking (x2)
480
120
Pilot
0.160.032-51
0.160.032-30
Efficiency Class
2
Nox Class
4
5.2.2 B-Fire 100 (PIN 0558CL1179)
Type
C11/C31
Gas type
G20
G20/G25
G25
G30/G31
G30/G31
G31
I2H,I2E,I2E+
I2ELL
I2L
I3B/P(30/50)
I3+
I3P(30,37,50)
Supply Pressure
mbar
20
20
25
30/50
28-30/37
30/37/50
Nominal Heat Input
Gross (Hs)
kW
14
14/11.4
12.8
9
9
8
Output
kW
8.8
8.8/7.2
8.0
5.6
5.6
5.0
Consumption
m³/hr
1.333
1.333/1.262
1.417
0.257
0.257
0.301
Burner Pressure (hot)
mbar
10.8
10.8
13.6
28.9
28.9
29.7
Injector Marking (x2)
560
120
Pilot
0.160.032-51
0.160.032-30
Efficiency Class
2
Nox Class
4