29
„interval 1“ - example
Multicontroller 7095 and at least two Turbelle®
electronic / stream.
Set the button (6) in such a way that the „interval 1“
LED lights up.
Connect at least one pump to the socket of „channel
1“ (1.1) or (1.2), and one to the socket of „channel
2“ (2.1) or (2.2).
In the aquarium, the pumps should be located on
opposite sides.
Use button (4) to set the interval time from „1 to 60
seconds“.
Set the adjustment knob (3) to middle position =
approx. 30 seconds.
« interval 1 » - exemple
Composants : Multicontroller 7095 et au minimum
deux pompes Turbelle® electronic / Turbelle®
stream.
Choisissez la fonction « interval 1 » à l’aide de la
touche (6).
Raccordez au minimum une pompe sur une prise
(1.1) ou (1.2) du canal « channel 1 » et une pompe
sur une prise (2.1) ou (2.2) du canal « channel 2 ».
Dans l’aquarium, les pompes doivent être placées
en ux opposé.
A l’aide de la touche (4), choisissez un temps
d’intervalles « 1 – 60 sec ».
Positionnez le bouton (3) en position médiane (=
env. 30 secondes).