Turbines Incorporated Cryogenic Flow Delivery System CDS1000 Manual (Rev E)
CDS1000 Page 10
3) Change System Settings (enter passcode)
1) Flowmeter size
3) Serial numbers and Bluetooth
Press “0” NO*, “1” YES
1) Totalize during alarm
(default 1000)
Press 1-9
1 – 1/2"
2 – 5/8"
3 – 3/4"
4 – 1.0"
5 – 1 1/4"
6 – 1 1/2"
7 – 2.0" *
8 – 3.0"
9 – 4.0"
2) Alarm and timer settings
2) Pump cooldown timer
3) Pump cooldown delay
4) Intermittent temp. tolerance
5) Pump ON during alarm
6) Count while temperature fail
Press “0” OFF, “1” ON*
Enter setting in seconds, press “ENT
Enter setting in seconds, press “ENT
Press “0” NO*, “1” YES
Press “0” OFF*,1” ON
(max 9999)
(max 9999)
Type value, press “ENT
1) Flowmeter
2) Pump cooldown timer
3) Pump cooldown delay
4) N/A
5) N/A
6) Bluetooth Authentication #
Type value, press “ENT
Type value, press “ENT
Type value, press “ENT
(max 9999)
Default 1234 for Turbines Bluetooth Printer
Next
Page
Next
Page
2) Totalize during alarm
3) Pump cooldown timer
4) Pump cooldown delay
5) Pump ON during alarm
6) Count while temperature fail
7) Pump shutdown pressure
8) Delivery threshold
9) Delivery pressure timer
0) Pump relay contacts
1) Max time between deliveries
Enter setting in seconds, press “ENT
(max 9999)
For units with added Pressure Pump Control :
For units without added
pressure pump control :
Enter setting in PSIG, press “ENT”
This is the minimum pressure allowed
before the Pump is disabled
Enter setting in PSIG, press “ENT”
This is the minimum normal discharge
pressure
Enter setting in seconds, press “ENT
This is the time the Delivery threshold
must be attained (achieved).
Press “0” N/C*,1” N/O
This is the setting for the active mode
of the PCO relay
(max 9999)
Suggested Values
LN2 LO2 LAR
75 75 75
150 175 225
180 180 180
* Default Value
7) Pump off @ flow rate err
Press “0” OFF*,1” ON