Turbines Incorporated Cryogenic Flow Delivery System CDS1000 Manual (Rev E)
CDS1000 Page 20
Programming a new Kfactor:
If equipped with a Program Enable Module (PEM) cut the lead seal wire and remove the
PEM. With the CDS1000 powered up normally, depress Setup and if not already in Prove
mode enter your password. Select Avg. Kfactor by depressing 1
Example: A new Kfactor is calculated to be 147; enter 147
Depress ESC to return to the Prover operating screen
To exit the Prove mode depress and hold the On/Off pushbutton until the
CDS1000 is off, then turn the unit back On.