OVEN OPERATION
9
Parameter Description Unit of Measure Minimum Value Maximum Value Default Value
P0 Temperatures shown in °C or °F (0 = °C, 1 = °F) n/a 0 1 1
P1 Temperatre Displays (0 = Actual, 1 = Setpoint) n/a 0 1 0
P2 Hysteresis Setting for Thermostat °F/°C 36°F/2°C 48°F/9°C 4°F/2°C
P3 O set of Top RTD °F/°C -22°F/-30°C 86/°F30°C 0°F/0°C
P4 Set Point Regulator (Top) °F/°C P5 P6 212°F/100°C
P5 Minimum Setting of Heater 1 °F/°C 32°F/0°C P6 122°F/50°C
P6 Maximum Setting of Heater 1 °F/°C P5 842°F/450°C 842°F/450°C
P7 O set of Bottom RTD °F/°C -22°F/-30°C 86/°F30°C 0°F/0°C
P8 Set Point Regulator (Bottom) °F/°C P9 P10 212°F/100°C
P9 Minimum Setting of Heater 2 °F/°C 32°F/0°C P10 122°F/50°C
P10 Maximum Setting of Heater 2 °F/°C P9 842°F/450°C 842°F/450°C
P11 Cooling Fans O Delay (K5 Relay) Minutes 0 60 30
P12 Fan 1 and 2 O Delay (K6 Relay) Minutes 0 60 30
P13 Keyboard Cooling Fan O Delay (K7 Relay) Minutes 0 60 30
P14 Preset Timer 1 Seconds P20 P21 80
P15 Preset Timer 2 Seconds P20 P21 90
P16 Preset Timer 3 Seconds P20 P21 100
P17 Preset Timer 4 Seconds P20 P21 110
P18 Preset Timer 5 Seconds P20 P21 120
P19 Preset Timer 6 Seconds P20 P21 130
P20 Minimum Settable Time Seconds 0 P21 0
P21 Maximum Settable Time Seconds P20 1,999 240
P22 Duration of Buzzer Sound Seconds 0 60 15
P23
Enable Over Temperature Alarm (0 = Disable, 1
= Enable)
n/a 0 1 0
P24 Over Temperature Alarm Threshold °F/°C 131°F/55°C 158°F/70°C 140°F/60°C
P25
Heater Modulation (0 = None, 1 = Voltage
Module determines)
n/a 0 1 1
P26 Heat Cycle Time Seconds 1 999 20
P27 Top Heater On Percentage % 0 100 67
P28 Bottom Heater On Percentage % 0 100 67
P29 Time between selection and timer start Seconds 2 20 2