OPERATING MANUAL
Balance Charger/Discharger
For LiPo/LiFe/LiIon/NiMH/NiCd/Pb Batteries
4 Ports Output
Question and Answer IconNeed help?

Do you have a question about the Turnigy 4x100W and is the answer not in the manual?

Summary

Understanding Your Turnigy 4 X100 W Charger Features

Optimized Software for Ease of Use and Safety

Features adjustable settings and AUTO charge for user safety and ease.

Integrated Lithium Battery Cell Balancer

Built-in balancer eliminates the need for an external unit.

Individual Cell Balance Discharging

Monitors and balances individual cells during discharge, alerting for abnormalities.

Compatibility with Lithium Battery Types

Supports charging of LiPo, LiFe, and Li-Ion batteries.

Fast and Storage Charge Modes

Offers modes to reduce charging time or prepare batteries for long-term storage.

Maximum Safety Features

Utilizes Delta-peak sensitivity to prevent overcharging.

Capacity Limit Termination

Automatically stops charging when user-specified capacity is reached.

Processing Time Limit Control

Automatically terminates processes if a set time limit is reached.

Programmable Battery Memory

Stores up to ten charge/discharge profiles for quick recall.

Continuous Charge;Discharge Cycles

Automates up to 5 cycles for battery refreshing and balancing.

Terminal Voltage Control (TVC)

Allows users to adjust the end voltage for charging/discharging.

LiPo Battery Meter Functionality

Enables checking total, highest, lowest, and individual cell voltages.

Exterior View of the Turnigy 4 X100 W Charger

Critical Warnings and Safety Guidelines

Standard Battery Parameter Reference

Table detailing nominal, max, storage, and discharge voltages for various battery types.

General Charging Safety Precautions

Connects charger first, avoid multiple batteries, and lists types of batteries not to charge.

Pre-Charge Operation Checklist

Verifies correct battery type, current, and secure connections before charging.

Charging Process Guidelines

Explains energy input, current calculation, lead requirements, and manufacturer instructions.

Discharging Process Guidelines

Explains residual capacity measurement, avoiding deep discharge, and memory effect for NiCd/NiMH.

Turnigy 4 X100 W Program Flow Chart

Lithium Polymer Balance Charge Program Connection

Connecting the Charger Unit

Details power input cables and required power supply specifications for connecting the charger.

Connecting the Battery Pack

Emphasizes parameter check before connection and correct sequence to avoid short-circuits.

Balance Socket Usage Guide

Guides on connecting the balance wire, maintaining correct polarity, and its use in balance charge mode.

Lithium Battery Charging and Discharging Programs

Charging Lithium Battery in Balance Mode

Balances cell voltages during charging using a balance lead for normalized charging.

Standard Lithium Battery Charging

Standard charging mode for Li-Po/Ion/Fe batteries without a balance lead.

FAST Lithium Battery Charging

Accelerates charging by reducing CV process duration, potentially reducing capacity slightly.

STORAGE Control for Lithium Batteries

Charges or discharges lithium batteries to optimal storage voltage based on type.

Lithium Battery Discharging Procedure

Guides on setting discharge current and final voltage, avoiding deep discharge.

Lead-Acid (Pb) Battery Program

Charging Lead-Acid (Pb) Batteries

Details charging parameters for Pb batteries, emphasizing slow charging and 1/10 capacity current.

Discharging Lead-Acid (Pb) Batteries

Explains setting discharge current and final voltage for lead-acid batteries.

NiMH and NiCd Battery Programs

Charging NiCd and NiMH Batteries

Describes charging NiCd and NiMH batteries using user-set current for R/C applications.

Discharging NiCd and NiMH Batteries

Outlines setting discharge current and final voltage for NiCd/NiMH batteries.

NiMH;NiCd Battery Cycle Programs

Details setting up charge/discharge cycles for battery conditioning, with adjustable number of cycles.

Battery Memory Setup and Management

Storing Battery Charge;Discharge Profiles

Guides on entering battery memory, setting type, voltage, and current for up to 10 profiles.

Saving and Loading Stored Profiles

Instructions on how to save a configured program and recall previously saved profiles.

Charger Program Setup Options

System Setup for Charging Processes

Configures rest time, safety time, and capacity cut-off settings for charging/discharging processes.

Operational Settings Configuration

Manages key beep, input power cut-off, internal temperature display, and loading factory settings.

Displaying Unit Serial Number and Version

Shows the serial number and software version of the charger unit.

LiPo Battery Meter Functions

Accessing the LiPo Battery Meter

Instructions on how to enter the LiPo Battery Meter function.

Monitoring Individual Cell Voltages

Displays individual cell voltages within a LiPo battery pack.

Viewing LiPo Pack Voltage Summary

Shows total, highest, and lowest voltages for the LiPo battery pack.

Information Displayed During Operation

Display of End Voltage and Input Power

Shows the final voltage and present input voltage during the process.

Internal Temperature and Timer Status

Indicates internal temperature and status of safety timer and capacity cut-off.

Real-time Cell Voltage Monitoring

Allows checking individual cell voltages when a balance lead is connected.

Warning and Error Message Reference

Polarity and Connection Error Codes

Covers reverse polarity, connection breaks, and general connector errors.

Input;Output Voltage Error Codes

Addresses short circuits, low input voltage, and high input voltage errors.

Cell Voltage and Connector Errors

Details errors for individual cell voltage (low/high) and incorrect connector setup.

Temperature and Control Failure Codes

Covers internal temperature issues and processor control failures.

Balance Mode and Battery Full Error Codes

Addresses invalid balance port usage and battery voltage exceeding settings.

Turnigy 4 X100 W Charger Specifications

Charger Operating and Power Specifications

Lists operating voltage, charge/discharge power, and current ranges.

Battery Compatibility and Limits

Details cell counts supported for various battery types and balancing current drain.

Physical Dimensions and Included Accessories

Provides net weight, dimensions, and a list of included accessories.

Product Warranty and Service Information

One-Year Limited Warranty Coverage

Outlines the one-year warranty coverage and exclusions for material or operational defects.

Turnigy 4x100W Specifications

General IconGeneral
BrandTurnigy
Model4x100W
CategoryBattery Charger
LanguageEnglish