Technical Specifications and Information
Dimensions: 6.75” (H) x 8.46” (W) x 4.12” (D)
Accuracy: ± 1.25 %
Repeatability: ± 0.25% at calibrated flow rate.
Flow Rate: 6 to 40 GPM
Pressure Rating: 50 psi
Construction: Aluminum
Units of Measure: ounces, pints, quarts, liters, gallons, 1 “Special Unit of Measure” option.
Counter: 4 digit resettable counter; (.01 9999 units).
Totalizers: 7 digit non-resettable “Master” totalizer, 7- digit resettable secondary.
Mounting Options: Can be installed for vertical or horizontal mounting by rotating display
accordingly.
Approvals: UL / cUL / ATEX Listing (see page 8 for information on specific certifications).
Power Supply: 2 “AA” batteries* (Alkaline or approved equivalent; Lithium optional for
extended battery life*); optional external power supply on certain models.
Expected Battery Life: 2 4 years of normal use with standard Alkaline batteries.
Operating Temperature Range:
900DB: -40 to 140 F (-40 to 60 C)