‘MX/MZX’ ADDRESSABLE FIRE CONTROLLERS
SERVICE AND MAINTENANCE INSTRUCTIONS FOR VERSION 17
LIST OF CONTENTS
1. GENERAL INFORMATION 3
2. ROUTINE CHECKS 4
2.1 GENERAL 4
2.2 WEEKLY CHECKS 4
2.3 THREE-MONTHLY CHECKS 4
2.4 ANNUAL CHECKS 5
2.5 THREE-YEARLY CHECKS 5
2.6 FOUR-YEARLY CHECKS 5
3. CONTROLLER FUNCTIONS 5
3.1 GENERAL 5
3.2 MOVING THE CURSOR 5
3.3 ENTERING INFORMATION 5
3.3.1 ENTERING PASSCODES 10
3.4 POINT DEFINITIONS 10
3.5 VALID VALUES 10
3.6 MAIN MENU 11
3.7 ACCEPT EVENTS 11
3.8 VIEW STATUS 11
3.9 ISOLATE/DE-ISOLATE 13
3.10 TIME/DATE 15
3.10.1 SET TIME/DATE 15
3.10.2 SUMMER/WINTER 15
3.11 EVENT LOG 15
3.11.1 VIEW EVENT LOG 15
3.11.2 PRINT EVENT LOG 16
3.11.3 FILTER 16
3.12 VIEW/PRINT DATA 16
3.12.1 VIEW/PRINT POINTS
ISOLATED 17
3.12.2 VIEW/PRINT POINTS
UNTESTED/FAILED 17
3.12.3 VIEW/PRINT POINT VALUES 17
3.12.4 VIEW FAULTS 17
3.12.5 VIEW LOOP POINT
COUNTERS 18
3.12.6 POINTS FORCED 19
3.12.7 ACTIVE POINTS 19
3.12.8 BY FUNCTION 20
3.13 SERVICE 21
3.13.1 WALK TEST 21
3.13.2 MAINTENANCE 23
3.13.3 DIAGNOSTICS 25
3.13.4 CONFIGURE DDM800 27
3.13.5 RESTART SYSTEM 27
3.13.6 SWITCHES 28
3.14 CONFIGURATION 29
3.14.1 CHANGE TEXT 29
3.14.2 INSERT POINT 33
3.14.3 DELETE POINT 34
3.14.4 MODIFY POINT 34
3.14.5 AUTOCONFIGURATION 35
3.15 TEST BUZZER/LEDs/
DISPLAY 37
4. DEFAULT SYSTEM POINTS 38
4.1 LOCAL I/0 (Field Interface Module/
CPU) 38
4.2 RBUS 39
4.3 ADDRESSABLE LOOP 37
5. DEVICE IDENTIFICATION AND
UNIVERSAL ADDRESSES 40
Question and Answer IconNeed help?

Do you have a question about the Tyco MX2 and is the answer not in the manual?

Tyco MX2 Specifications

General IconGeneral
BrandTyco
ModelMX2
CategoryController
LanguageEnglish

Summary

General Information

Periodic Checks and Servicing

Details the scheduled checks and servicing requirements for the MX/MZX fire controller system.

Routine Checks

Routine Check Procedures

Covers general, weekly, and three-monthly checks for system maintenance.

Controller Functions

Basic Navigation and Input

Covers general controller functions, cursor movement, and data entry procedures.

Point Definitions and Values

Defines point types (Real, Pseudo) and lists valid input values for system parameters.

Main Menu and Event Handling

Navigating the main menu and accepting system events or alarms.

Isolate/De-Isolate Points

Procedures for isolating or de-isolating system points, detectors, or sounders.

Time/Date and Event Log

Setting system time/date and viewing/printing the event log.

View and Print Data

Options for viewing and printing various system data like points, faults, and counters.

Service Functions

Introduction to the service menu, including walk test, maintenance, and diagnostics.

System Configuration

Procedures for configuring system parameters, including text modification and point management.

System Testing

Performing tests on the buzzer, LEDs, display, and other system diagnostics.

Default System Points

Local I/O and RBUS Points

Default system points for Local I/O and RBUS, covering REAL and PSEUDO types.

XBUS and Addressable Loop Points

Default system points for XBUS and Addressable Loop categories.

Device Identification and Universal Addresses

Device Identification and Addresses

Explains device identification, universal addresses, and their structure.

Related product manuals