RE-USE AFTER LONG TERM STORAGE
Carry out a full check of all oils and coolant.
Refit the battery and run the engine at idle for 30 min. to ensure optimum engine life.
IMPORTANT
After refilling the engine with the coolant run the engine for approx. 5-10 min. at 1,500 ~ 2,000rpm every
month as a corrosion prevention measure.
Either removes the battery or the negative terminal as mouse damage to wiring can cause short circuits and
fires.
Remove the ignition key and store in a safe place.
LONG-TERM STORAGE.
When the tractor will not be used for a long time carry out the cleaning as for short term storage.
Drain the oil and replace with new oil.
Run the engine for approx. 5 min. to ensure that it has new oil throughout the engine.
Drain the coolant from the radiator and remove the ignition key.
Attach a tag both the key and the steering wheel saying “No coolant”.
Lubricate all grease and oil points on the tractor.
Check the pressures and add a small amount of extra pressure.
Lower any implement to the ground or store in a shady dry place.
Place a piece of wood under each tire to preserve the tire.
MAINTENANCE AND SERVICE
5-21