TRACTOR INSTRUMENTS
C
18
<How to disengage coupler>
1. Lower the implement on the
ground to release pressure in the
hydraulic hose.
2. Stop the engine and operate the
remote hydraulic lever to remove
any residual pressure in the hose.
3. Disconnect the male coupler on the
implement side while moving its
external ring on the tractor side
backward slightly.
4. Wipe oil and dust from the coupler
and plug the dust cover.
REMOTE CONTROL VALVE
<How to engage coupler>
1. Clean the couplers on the tractor
and implement thoroughly.
2. Remove the dust cover from the
tr
actor side. Then, fit the male
coupler on the implement side
while moving its external ring
backward slightly.
3. Pull the ma
le coupler on the
implement side backward slightly
to check its firm engagement.
To prevent a burn and skin damage,
make sure to stop the engine before
connecting or disconnecting the
coupler.
Do not use your hands to check for oil
leakage.
WARNING