firmware download in their application processor, will need to replace the software. A template is available from
your u-blox support team.
Please refer to the u-blox 6 Receiver Description including Protocol Specification [3]
for more information. This
document is available on the
ublox website.
B.3 Hardware Migration
B.3.1 Hardware Migration: ANTARIS 4 u-blox 6
u-blox 6 modules have been designed with backward compatibility in mind but some minor differences were
unavoidable. These minor differences will however not be relevant for the majority of the ANTARIS 4 designs.
Good performance requires a clean and stable power supply with minimal ripple. Care needs to be exercised in
selecting a strategy to achieve this. Avoid placing any resistance on the Vcc line. For better performance, use an
LDO to provide a clean supply at Vcc and consider the following:
Special attention needs to be paid to the power supply requirements as u-blox 6 has higher currents than
ANTARIS 4 (peak currents & backup current see datasheet for further details)
Wide power lines or even power planes are preferred.
Place LDO near the module.
Avoid resistive components in the power line (e.g. narrow power lines, coils, resistors, etc.).
Placing a filter or other source of resistance at Vcc can create significantly longer acquisition
times.
B.3.2 Hardware Migration: u-blox 5 u-blox 6
Check the pins RxD1 and EXTINT0 regarding the input voltage threshold.
For more information see the LEA-6 Data Sheet [1] and LEA-5 Data Sheet [7].
B.4 Migration of LEA modules
B.4.1 Migration from LEA-4 to LEA-6
See also the migration Table in the u-blox5 Hardware Integration Manual.
For u-blox6 the Input Voltage thresholds on the pins RXD1 and EXTINT0 have changed.
The Safeboot functionality is inverted compared to Antaris receivers.
VCC_OUT is now VCC and not 1.8 V as on Antaris Modules.
Also check your power supply requirements with the datasheet (for VCC and VBCKP).
Pin
LEA-4H/LEA-4P/LEA-4T LEA-6H/LEA-6T Remarks for Migration
Pin Name Typical Assignment Pin Name Typical Assignment
1 Reserved
VDDIO level I/O;
not connected
SDA2 NC
2 Reserved
VDDIO level I/O;
not connected
SCL2 NC
3 TXD1 VDDIO level I/O TxD1 Output
4 RXD1 VDDIO level I/O RxD1 Input Leave open if not used.
5 VDDIO 1.65 3.60V NC Connect to VCC
Can be left open, but connection to VCC is
recommended for compatibility reason. With LEA-
6H the I/O voltage is always VCC.
6 VCC 2.70 3.30V VCC 2.70 3.60V
Extended power supply range, higher peak supply
current.
7 GND GND GND GND No difference
8 VDD18OUT NC VCC_OUT NC
Internally connected to VCC, if you have circuitry
connected to this pin, check if it withstands the