EasyManuals Logo

u-blox SARA-G3 Series User Manual

u-blox SARA-G3 Series
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
SARA-G3 series - System Integration Manual
UBX-13000995 - R06 Objective Specification System description
Page 48 of 218
All flow control handshakes are supported by the UART interface and can be set by appropriate AT
commands (see
u-blox AT Commands Manual
[2], &K, +IFC, \Q AT commands): hardware flow control
(RTS/CTS), software flow control (XON/XOFF), or none flow control.
Hardware flow control is enabled by default.
The following baud rates can be configured by AT command:
2400 b/s
4800 b/s
9600 b/s
19200 b/s
38400 b/s
57600 b/s
115200 b/s, default value when the autobauding is disabled
The following baud rates are available with autobauding only:
1200 b/s
230400 b/s
Autobauding is enabled by default.
The following frame formats can be configured by AT command:
8N1 (8 data bits, No parity, 1 stop bit), default frame configuration with fixed baud rate
8E1 (8 data bits, even parity, 1 stop bit)
8O1 (8 data bits, odd parity, 1 stop bit)
8N2 (8 data bits, No parity, 2 stop bits)
7E1 (7 data bits, even parity, 1 stop bit)
7O1 (7 data bits, odd parity, 1 stop bit)
Automatic frame recognition is supported and enabled by default in conjunction with the auto-
bauding. When auto-bauding is active, the auto-framing is enabled overruling the frame format
setting.
Figure 16Figure 16 describes the 8N1 frame format, which is the default configuration with fixed baud rate.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the u-blox SARA-G3 Series and is the answer not in the manual?

u-blox SARA-G3 Series Specifications

General IconGeneral
Brandu-blox
ModelSARA-G3 Series
CategoryGSM/GPRS Modules
LanguageEnglish