NEVER attempt to repair or perform maintenance on the unit until the main
electrical power has been disconnected.
1. Will not eject ice (water frozen)
Cause Remedy
Control setting too cold Adjust control warmer (counterclockwise)
Control defective (1-2 contacts open) Replace control
Bin switch defective Replace bin switch
Limit switch defective (open) Replace limit switch
Ice maker assembly motor stalled Replace motor
Broken wire in ice maker circuit Repair or replace wiring
Water soaked cabinet insulation Replace foamed cabinet assembly
Dirty condenser Clean condenser
2. Will not fill with water
Cause Remedy
Water supply valve closed Open water supply valve
Water switch defective (open) Replace water switch
Solenoid valve defective Replace solenoid valve
Fill tube outlet frozen Replace solenoid valve and defrost fill tube
Broken wire in water fill circuit Repair or replace wiring
3. Will not stop making ice
Cause Remedy
Bin switch defective (closed) Replace bin switch
Bin arm binding Lubricate bin arm pivot points or loosen
bin arm lever screw
4. Water will not stop filling
Cause Remedy
Water switch defective (closed) Replace water switch
Solenoid valve defective Replace solenoid valve
Stalled ice maker motor Replace motor
Temperature control defective. Replace temperature control
Ice maker is in continuous harvest
cycle (contacts 1-2 closed)
5. Ejector blades will not stop turning
Cause Remedy
Control defective (1-2 contacts will Replace control
not open)
Hold switch defective Replace hold switch
Defective wiring Repair or replace wiring
Short in mold heater Replace heater
! !
TROUBLESHOOTING