27
■ Water line leaking at solenoid valve outlet ■ Replace water line and fitting
■ Water line leaking at fill tube ■ Tighten clamp or fill tube replace fill tube
assembly
■ Defrost drain line not in drain pan ■ Position drain line in drain pan
■ Crack in water line ■ Replace water line
13. Water leak (inside unit)
Cause Remedy
■ Ice maker assembly fill cup obstructed ■ Remove obstruction.
■ Fill ice cup and fill tube out of alignment ■ Align fill tube and fill cup
■ Water level too high ■ Adjust water level
■ Defrost drain plugged ■ Ice in drain trough (refer to #16)
14. Excessive frost build-up
Cause Remedy
■ Door gasket not sealing properly ■ Adjust door hinges or replace door gasket
■ Door out of alignment ■ Adjust door hinges
■ Water soaked cabinet insulation ■ Replace foamed cabinet assembly
(factory repair only)
■ Light stays on when door is closed■ Repair or adjust light bracket
15. Noisy
Cause Remedy
■ Copper refrigeration tube touching cabinet ■ Carefully adjust tubing
■ Fan blade touching shroud ■ Adjust fan mounting or shroud
■ Fan blade obstruction (wiring, foam ■ Remove obstruction
insulation, packaging material)
16. Ice build-up in drain trough or drainage problem (see page 20)
Cause Remedy
■ Obstructed drain cup or tube ■ Clear obstruction
■ Evaporator not touching drain trough ■ Reposition evaporator to contact
drain
trough along entire length
■ Kinked drain tube ■ Reroute drain tube
■ Drain trough spout and drain cup ■ Align drain trough and drain cup
not aligned
17. Unit will not defrost
Cause Remedy
■ Bypass valve bent (will not operate) ■ Align bypass valve and coil assem-
bly
■ Bypass coil defective■ Replace bypass valve
■ Defrost timer defective ■ Replace defrost timer
■ Bypass valve defective ■ Replace bypass valve
18. Fresh food temperature too cold
Cause Remedy
■ Ice bucket not fully inserted ■ Push ice bucket in place
■ Temperature control set too cold ■ Adjust control to warmer setting
(counterclockwise)
■ Air leak at evaporator cover ■ Seal cover with RTV