PAGE 1 OF 3 0524 TH-1485
STANDARD LIFT TABLE
1-800-295-5510
uline.com
H-1485, H-1486
H-1487, H-6754
TROUBLESHOOTING
OPERATING ISSUE CAUSES RECOMMENDATIONS
Does not reach the full
lift height.
Steel ball of the check-valve is not fully
seating.
Firing pin does not allow the steel ball to
fully seat.
Low hydraulic oil.
Clean the valve opening and replace
the steel ball.
Adjust the tension rate of the steel wire
connected to the hand lever to adjust
the seating of the firing pin.
Add hydraulic oil.
The table rises then
descends.
Steel ball of the check-valve is not fully
seating.
Firing pin does not allow the steel ball to
fully seat.
Clean the valve opening and replace
the steel ball.
Adjust the tension rate of the steel wire
connected to the hand lever to adjust
the seating of firing pin.
The table board does
not descend.
The travel of the firing pin is not enough
to open the steel ball.
Adjust the tension rate of the steel wire
rope to make firing pin at suitable
place and apply lubricant to the pin.
Oil leakage at firing pin.
The O-ring is damaged. Change pump.
Oil leakage at pump.
The seal ring is damaged.
Change hydraulic oil.
Change pump.
1) Unscrew sealing screw with a wrench.
2) Lift the hand lever.
3) Twist off screw of the oil plug and fill
pump with hydraulic oil.
Table will not rise.
Cable may be disconnected. Ensure cable with silver sleeve is
terminating inside of nut.
(See Figures 1-3)
Para Español, vea página 2.
Pour le français, consulter la page 3.
Figure 2
Figure 3
Cable
with Boot
Correct
Cable Insertion
Incorrect
Cable Insertion
Figure 1