EasyManuals Logo

Ublox NEO-M8N-0-11 User Manual

Ublox NEO-M8N-0-11
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
NEO-8Q / NEO-M8 - Hardware integration manual
UBX-15029985 - Production information Migration to u-blox 8 / M8 modules Page 18 of 19
C1-Public
NEO-6 NEO-8Q and NEO-M8 series Remarks for migration
Pin name
Typical
assignment
Pin name
Typical
assignment
11 RF_IN
GNSS signal
input
RF_IN GNSS signal input No difference
12 GND GND GND GND No difference
13 GND GND GND GND No difference
14 MOSI/
CFG_COM0
SPI MOSI /
configuration
pin.
Leave open if
not used.
LNA_EN
Used to turn an
optional external
LNA on and off
LNA_EN (Active Antenna Control) can be used to
turn an optional external LNA on and off.
-> Different functions, no SPI MOSI and
configuration pins with NEO-8Q / NEO-M8. If not
used as default configuration, it must be set
using software command!
It is not possible to migrate from NEO-6 to NEO-
8Q / NEO-M8 if NEO-6 pin 14 is connected to
GND. In this case, migrate to NEO-M8M!
15 MISO/
CFG_COM1
SPI MISO /
configuration
pin. Leave
open if not
used.
RESERVED Leave open
16 CFG_GPS0/
SCK
Power mode
configuration
pin / SPI
clock. Leave
open if not
used.
RESERVED Leave open
17 RESERVED Leave open RESERVED Leave open No difference
18 SDA DDC data SDA
DDC data / SPI
CS_N
No difference for DDC. If pin 2 low = SPI chip
select
19 SCL DDC clock SCL
DDC clock / SPI
SCK
No difference for DDC. If pin 2 low = SPI clock
20 TxD Serial port TXD
UART_TX / SPI
MISO
No difference for UART. If pin 2 low = SPI MISO
21 RxD Serial port RXD
UART_RX / SPI
MOSI
No difference for UART. If pin 2 low = SPI MOSI
22 V_BCKP
Backup
supply
voltage
V_BCKP
Backup supply
voltage
Check current in Data sheet.
If in u-blox 6 module this was connected to GND,
you can do the same in u-blox M8/8.
23 VCC
Supply
voltage
NEO-6Q /
M/P/V/T:
2.7 3.6 V
NEO-6G:
1.75 – 1.95 V
VCC Supply voltage
NEO-8Q /
NEO-M8N/Q/J:
2.7 3.6 V
NEO-M8M:
1.653.6 V
No difference for NEO-8Q / NEO-M8J/N/Q
Extended supply voltage range for NEO-M8M
24 GND GND GND GND No difference
Table 4: Pin-out comparison NEO-6 vs. NEO-8Q and NEO-M8 series
Make sure that the RF path (antenna and filtering) matches that of the GNSS constellations used.
3.3 Software migration
For an overall description of the module software operation, see the u-blox 8 / u-blox M8 Receiver
Description including Protocol Specification [4].
For migration, see the u-blox M8 FW SPG3.01 Migration Guide [9].